8. Main Remote Setting
24
A16381TMF2
Function Main Sub
Power Saving Details Setting
×
Outdoor Unit
Capacity Control
Details Setting
×
Power Savings Level Switch
×
Indoor Unit
Rotation Control
Details Setting
×
ON/OFF
Intermittent Control
Details Setting
Power Savings Level Switch
Night Quiet Operation
×
Power Savings Schedule
Outdoor Capacity Control
×
Intermittent Control
Night Quiet Operation Schedule
×
Power Up Setting
×
Autoboost
Table D. Relation between Main/Sub Controller and Setting Range
Concerning main and sub controllers, the range of settings may dier for the functions shown below.
: Available
×
: Not Available
Step4. When the change to main remote control is completed, the "Reconfigure each setting" screen is
displayed.
Step5. Press "OK" on the confirmation screen to return to Installation Menu.
Step3. Select "Yes" and press "OK" to change to the main remote.
"Change to main remote" is displayed on the screen.
Select "Cancel" to return to Step2.
*After the change is completed, the Power Savings Mode
will change to "No Setting". After the following functions
initialized, reset the setting for the "Power Savings Setting",
"Power Saving/Night Quiet Schedule", "Night Quiet Operation",
"Priority Setting" and "Power Up Setting" .
Changing from the sub controller to the main controller.
Step1. Select "Installation Menu" on the Service & Installation screen by pressing " " and press "OK".
Step2. Select "Main Remote Setting" by pressing " " or " " and press "OK".
(Mon) 16:30
Installation Menu
Main Remote Setting
Priority Setting
Cancel preheating control
Setting Initialization
Address Initialization
OK
Enter Back
Change to main remote even if
each settings is initialized?
OK
Select Back
Yes Cancel
NOTES:
When using two controllers, only the primary controller can be set as the main controller. In cases where
two controllers are both sub controllers, the "Main Remote Setting" is only accessible from the primary
controller.
In cases where the primary controller is a "Main Controller" and the secondary controller is a "Sub
Controller", when the primary controller and the secondary controller are changed by the function selection,
Main and Sub controllers will also be switched simultaneously.
If the sub controller is displayed, the main remote controller may not function normally. Please verify the
cable connection.
If a remote control group is operating with multiple refrigerant systems, the ECO function may not operate
normally.