Preparations 2-9
Hitachi Compute Blade Embedded 10G DCB Switch Module License Installation Guide
Compute Blade 2500
Note1: CB500 chassis supports Zero origin IOSW slot numbering. So you can
input IOSW slot#0, 1, 2 or 3. On the other hands, CB2500 chassis supports
“One” origin IOSW slot numbering. So you can input IOSW slot #1, 2.
(3)Disconnect from the Compute Blade Server
After all work, disconnect from 10G DCB switch module and the management
module.
The following shows the disconnect procedure for Compute Blade 2000.
Enter "exit" to exit from the 10G DCB switch module. Press Enter key after
"Hit enter key" is displayed. And, enter "X" to exit from the CB2000
management module.
sw0# exit Enter exit
Connection closed by foreign host.
Entering character mode
Escape character is '^]'.
- Connection closed.
Hit enter key.
(0)$ change console -s 1 –F
↑ Enter slot number (1 or 2. See Note1)
Network OS (sw0)
x.x.x_xxx (<- Indicates NOS version)
sw0 login: admin Enter User ID of administrator (admin).
Password: xxxxx Enter Password
WARNING: The default password of 'admin' and 'user' accounts have
not been changed.
Welcome to the Brocade Network Operating System Software
admin connected from 0.0.0.0 using console on sw0
sw0#