23
RS-232C Communication / Network command table (continued)
Names Operation Type Header
Command Data
CRC Action Type Setting Code
PERFECT FIT Left
Bottom -V
Get BE EF 03 06 00 45 88 02 00 26 21 00 00
Increment BE EF 03 06 00 23 88 04 00 26 21 00 00
Decrement BE EF 03 06 00 F2 89 05 00 26 21 00 00
PERFECT FIT Right
Bottom -H
Get BE EF 03 06 00 B9 89 02 00 27 21 00 00
Increment BE EF 03 06 00 DF 89 04 00 27 21 00 00
Decrement BE EF 03 06 00 0E 88 05 00 27 21 00 00
PERFECT FIT Right
Bottom -V
Get BE EF 03 06 00 AD 8A 02 00 28 21 00 00
Increment BE EF 03 06 00 CB 8A 04 00 28 21 00 00
Decrement BE EF 03 06 00 1A 8B 05 00 28 21 00 00
PERFECT FIT Reset Execute BE EF 03 06 00 D5 8A 06 00 29 21 00 00
PERFECT FIT Left Side
Distortion
Get BE EF 03 06 00 31 97 02 00 41 21 00 00
Increment BE EF 03 06 00 57 97 04 00 41 21 00 00
Decrement BE EF 03 06 00 86 96 05 00 41 21 00 00
PERFECT FIT Right
Side Distortion
Get BE EF 03 06 00 75 97 02 00 42 21 00 00
Increment BE EF 03 06 00 13 97 04 00 42 21 00 00
Decrement BE EF 03 06 00 C2 96 05 00 42 21 00 00
PERFECT FIT
Distortion Position V
Get BE EF 03 06 00 89 96 02 00 43 21 00 00
Increment BE EF 03 06 00 EF 96 04 00 43 21 00 00
Decrement BE EF 03 06 00 3E 97 05 00 43 21 00 00
PERFECT FIT Top Side
Distortion
Get BE EF 03 06 00 FD 97 02 00 44 21 00 00
Increment BE EF 03 06 00 9B 97 04 00 44 21 00 00
Decrement BE EF 03 06 00 4A 96 05 00 44 21 00 00
PERFECT FIT Bottom
Side Distortion
Get BE EF 03 06 00 01 96 02 00 45 21 00 00
Increment BE EF 03 06 00 67 96 04 00 45 21 00 00
Decrement BE EF 03 06 00 B6 97 05 00 45 21 00 00
PERFECT FIT
Distortion Position H
Get BE EF 03 06 00 45 96 02 00 46 21 00 00
Increment BE EF 03 06 00 23 96 04 00 46 21 00 00
Decrement BE EF 03 06 00 F2 97 05 00 46 21 00 00
PERFECT FIT All Sides
Reset
Execute BE EF 03 06 00 3D 96 06 00 47 21 00 00
PERFECT FIT Memory
Save-1
Execute BE EF 03 06 00 29 95 06 00 48 21 00 00
PERFECT FIT Memory
Save-2
Execute BE EF 03 06 00 D5 94 06 00 49 21 00 00
PERFECT FIT Memory
Save-3
Execute BE EF 03 06 00 91 94 06 00 4A 21 00 00
PERFECT FIT Memory
Load-1
Execute BE EF 03 06 00 6D 95 06 00 4B 21 00 00
PERFECT FIT Memory
Load-2
Execute BE EF 03 06 00 19 94 06 00 4C 21 00 00
PERFECT FIT Memory
Load-3
Execute BE EF 03 06 00 E5 95 06 00 4D 21 00 00
PERFECT FIT Test
Pattern
Set
OFF BE EF 03 06 00 16 94 01 00 4E 21 00 00
ON BE EF 03 06 00 86 95 01 00 4E 21 01 00
Get BE EF 03 06 00 25 94 02 00 4E 21 00 00
AUTO ECO MODE
Set
OFF BE EF 03 06 00 F2 89 01 00 10 33 00 00
ON BE EF 03 06 00 6B 26 01 00 10 33 01 00
Get BE EF 03 06 00 C8 27 02 00 10 33 00 00
(continued on next page)