54
OPTION menu 
Item Description
SERVICE
(continued)
COMMUNICATION
(continued)
RESPONSE LIMIT TIME
This menu is available only when the NETWORK 
BRIDGE is selected for the COMMUNICATION 
TYPE and the HALF-DUPLEX is selected for the 
TRANSMISSION METHOD.
Select the time period to wait for receiving response 
data from other devise communicating by the 
NETWORK BRIDGE and the HALF-DUPLEX through 
the
CONTROL OUT port.
OFF
Ù
 1s
Ù
 2s
Ù
 3s
OFF: Select this mode if it is not required to check the 
responses from the devise that the projector sends data 
to. In this mode, the projector can send out data from 
the computer continuously.
1s/2s/3s: Select the time period to keep the projector 
waiting for response from the device that the projector 
sends data to. While waiting the response, the projector 
does not send out any data from the 
CONTROL OUT 
port.
BYTES INTERVAL TIMEOUT
This menu is available only when NETWORK BRIDGE 
is selected for the COMMUNICATION TYPE and HALF-
DUPLEX is selected for the TRANSMISSION METHOD.
Select the blank time length to judge that the response 
data has fi nished in the communicating in the condition 
of the NETWORK BRIDGE and the HALF-DUPLEX 
through the 
CONTROL OUT port.
50ms
Ù
100ms
Ù
150ms
Ù
200ms
•
50ms is selected as the default setting.
NOTE
• OFF is selected as the default setting.
NOTE