53
Please check and clean the air lter periodically. When the indicators or a
message prompts you to clean the air lter, comply with it as soon as possible.
Replace the air lter when it is damaged or too soiled. To prepare a new air lter,
contact your dealer and tell the air lter type number.
Type number : MU04951
When you replace the lamp, please replace the air lter. An air lter of specied
type will come together with a replacement lamp for this projector.
Cleaning the air lter
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufciently cool down.
2.
Use a vacuum cleaner on and around the lter
cover.
3.
Pull the lter cover knobs while lifting it. The lter
unit which consists of the lter cover, air lter and
lter frame will come off.
4.
Use a vacuum cleaner for the lter vent of the
projector and the lter frame side of the lter unit.
If the air lter is damaged or too soiled, replace it
according to the following procedure number 5 to 7.
Otherwise, please jump to the procedure number 8.
5.
Pull the lter frame’ knob up while holding the lter
cover. The lter frame will come off and the air
lter will appear.
6.
Replace the air lter with new one.
7.
Put the lter frame back.
8.
Put the lter unit back into the projector.
9.
Turn the projector on and reset the lter time using
the FILTER TIME item in the EASY MENU.
(1) Press the MENU button to display a menu.
(2)
Point at the “FILTER TIME” using the ▼/▲ button, then press the ► button. A dialog will appear.
(3) Press the ▲ button to select “RESET” on the dialog. It performs resetting the lter time.
Maintenance
Air lter
NOTE • Please reset the lter time only when you have cleaned or
replaced the air lter, for a suitable indication about the air lter.
• The projector may display the message such as “CHECK THE AIR FLOW”
or turn off the projector, to prevent the internal heat level rising.
WARNING ►Before taking care of the air lter, make sure the power cable
is not plugged in, then allow the projector to cool sufciently.
Use only the air lter of the specied type. Do not use the projector without the
air lter or the lter cover. It could result in a re or malfunction to the projector
.
Clean the air lter periodically. If the air lter becomes clogged by dust or the like,
internal temperatures rise and could cause a re, a burn or malfunction to the projector.
Filter cover
Filter cover knobs
Filter unit
Filter cover
Filter frame
Air lter