Hitachi EUP-B712 - User Manual

Hitachi EUP-B712
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
BiopsyProbe
EUPB712
INSTRUCTIONMANUAL
Notesforoperatorsandresponsiblemaintenancepersonnel
PleasereadthroughthisInstructionManualcarefullypriortouse.
Keep this Instruction Manual together with the system with care to
makeitavailableanytime.
Tokyo,Japan
Q1EEP14124
©Hitachi,Ltd.2013,2017.Allrightsreserved.
0123
Question and Answer IconNeed help?

Do you have a question about the Hitachi EUP-B712 and is the answer not in the manual?

Summary

About this Instruction Manual

Graphical Symbols and Definitions

General Probe Information

Principles of Operation

Explains how the probe and scanner work together using ultrasonic waves to create images.

Intended Use and Components

Details the probe's intended applications, prohibited uses, and lists its standard components.

Optional Accessories

Lists optional accessories like the magnetic sensor and needle guide bracket kits, and their purchase sources.

External View and Parts

Illustrates and labels the external components of the EUP-B712 probe, including immersible parts.

Pre-Use Inspection Procedures

Probe and Connection Inspection

Details visual checks for probe damage, proper connection, and avoidance of unauthorized attachments.

Needle Guide Bracket and Accessory Inspection

Covers visual inspection of the needle guide bracket, magnetic sensor, and spacer for damage and functionality.

Probe Operation and Attachments

Probe Connection and Basic Operation

Covers probe connection, scanner operation, image orientation, and use of sterile probe covers.

Needle Guide Bracket Operations

Details fitting, placing, attaching, and setting the needle guide bracket and needle inserts.

Magnetic Sensor Attachment Operations

Explains how to attach and remove magnetic sensor attachments (EZU-RV2S and EZU-RV3S) for RVS.

Magnetic Sensor Attachment Usage

Attaching and Removing Magnetic Sensors

Provides step-by-step instructions for attaching and removing both EZU-RV2S and EZU-RV3S magnetic sensors.

Probe Reprocessing and Sterilization

Reprocessing Requirements and Flowchart

Covers reprocessing levels, warnings, transportation, and presents a flowchart for the entire process.

Probe Cleaning and Disinfection

Outlines pre-cleaning, manual cleaning, and manual disinfection procedures for the probe and its attachments.

Probe Drying, Packaging, and Sterilization

Details drying methods, packaging for sterilization, sterilization conditions, and storage guidelines.

Needle Guide Bracket Reprocessing

EZU-PA7 C2 Manual Reprocessing

Guides on pre-cleaning, manual cleaning, and manual disinfection of the needle guide bracket parts.

EZU-PA7 C2 Automated Reprocessing

Details the parameters and steps for automated cleaning and disinfection of the needle guide bracket.

EZU-PA7 C2 Post-Reprocessing Steps

Explains drying, packaging, assembly, inspection, and storage procedures for the needle guide bracket.

Maintenance and Safety Inspection

Probe Maintenance and Inspection

Details post-use care and visual inspection of the probe head, housing, cable, and connector for damage.

Accessory Maintenance and Inspection

Covers cleaning, storage, and inspection of the magnetic sensor attachment and needle guide bracket for damage.

Critical Safety Precautions

Probe Usage and Biopsy Safety

Warns against using a damaged probe and emphasizes using the needle guide bracket for biopsy procedures.

General Operational Safety

Provides cautions on exposure time, connector protection, handling, and cleaning of sensitive parts.

Technical Specifications and Approved Products

Probe Specifications and Suppliers

Details the probe's technical specifications and lists approved suppliers and products for use.

Needle Guide Bracket Specs and Suppliers

Provides specifications for the needle guide bracket and lists its approved suppliers and products.

Proper Probe Disposal

Summary

About this Instruction Manual

Graphical Symbols and Definitions

General Probe Information

Principles of Operation

Explains how the probe and scanner work together using ultrasonic waves to create images.

Intended Use and Components

Details the probe's intended applications, prohibited uses, and lists its standard components.

Optional Accessories

Lists optional accessories like the magnetic sensor and needle guide bracket kits, and their purchase sources.

External View and Parts

Illustrates and labels the external components of the EUP-B712 probe, including immersible parts.

Pre-Use Inspection Procedures

Probe and Connection Inspection

Details visual checks for probe damage, proper connection, and avoidance of unauthorized attachments.

Needle Guide Bracket and Accessory Inspection

Covers visual inspection of the needle guide bracket, magnetic sensor, and spacer for damage and functionality.

Probe Operation and Attachments

Probe Connection and Basic Operation

Covers probe connection, scanner operation, image orientation, and use of sterile probe covers.

Needle Guide Bracket Operations

Details fitting, placing, attaching, and setting the needle guide bracket and needle inserts.

Magnetic Sensor Attachment Operations

Explains how to attach and remove magnetic sensor attachments (EZU-RV2S and EZU-RV3S) for RVS.

Magnetic Sensor Attachment Usage

Attaching and Removing Magnetic Sensors

Provides step-by-step instructions for attaching and removing both EZU-RV2S and EZU-RV3S magnetic sensors.

Probe Reprocessing and Sterilization

Reprocessing Requirements and Flowchart

Covers reprocessing levels, warnings, transportation, and presents a flowchart for the entire process.

Probe Cleaning and Disinfection

Outlines pre-cleaning, manual cleaning, and manual disinfection procedures for the probe and its attachments.

Probe Drying, Packaging, and Sterilization

Details drying methods, packaging for sterilization, sterilization conditions, and storage guidelines.

Needle Guide Bracket Reprocessing

EZU-PA7 C2 Manual Reprocessing

Guides on pre-cleaning, manual cleaning, and manual disinfection of the needle guide bracket parts.

EZU-PA7 C2 Automated Reprocessing

Details the parameters and steps for automated cleaning and disinfection of the needle guide bracket.

EZU-PA7 C2 Post-Reprocessing Steps

Explains drying, packaging, assembly, inspection, and storage procedures for the needle guide bracket.

Maintenance and Safety Inspection

Probe Maintenance and Inspection

Details post-use care and visual inspection of the probe head, housing, cable, and connector for damage.

Accessory Maintenance and Inspection

Covers cleaning, storage, and inspection of the magnetic sensor attachment and needle guide bracket for damage.

Critical Safety Precautions

Probe Usage and Biopsy Safety

Warns against using a damaged probe and emphasizes using the needle guide bracket for biopsy procedures.

General Operational Safety

Provides cautions on exposure time, connector protection, handling, and cleaning of sensitive parts.

Technical Specifications and Approved Products

Probe Specifications and Suppliers

Details the probe's technical specifications and lists approved suppliers and products for use.

Needle Guide Bracket Specs and Suppliers

Provides specifications for the needle guide bracket and lists its approved suppliers and products.

Proper Probe Disposal

Hitachi EUP-B712 Specifications

General IconGeneral
CategoryMedical Equipment
ModelEUP-B712
ManufacturerHitachi
TypeUltrasound
DisplayLCD Monitor
Power SupplyAC Power