EasyManua.ls Logo

Hitachi HUS VM - Page 432

Hitachi HUS VM
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
raidcom replace snapshot
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
S-VOL of a Thin Image pair or a Copy-on-Write
Snapshot pair.
CMDRJE Executing 2E10 003E The command ends abnormally because the
volume of Universal Replicator pair for the delta
resync operation is specified as the S-VOL of a Thin
Image pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E10 0045 The command ends abnormally because the P-VOL
of a TrueCopy pair is specified as the S-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E10 0046 The command ends abnormally because the S-VOL
of a TrueCopy pair is specified as the S-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E10 0056 The specified volume cannot be used for the Thin
Image pair operation because the virtual LDEV ID
is deleted.
CMDRJE Executing 2E10 005B The Thin Image pair operation cannot be
performed because the virtual storage machine of
the specified P-VOL is different from the virtual
storage machine of the specified S-VOL.
CMDRJE Executing 2E10 0060 The command ends abnormally because the
specified S-VOL is not assigned to a Thin Image
pair.
CMDRJE Executing 2E10 0061 The specified volume cannot be used for the Thin
Image pair operation because the virtual LDEV ID
is deleted.
CMDRJE Executing 2E10 0204 The operation failed because the specified LDEV
which is holding the attribute of SLU is bind to the
LDEV which is holding the attribute of ALU.
CMDRJE Executing 2E10 9709 The command ends abnormally because the
specified Thin Image pair is not exist.
CMDRJE Executing 2E10 970B The command ends abnormally because the
specified Thin Image pair is assigned to an S-VOL.
CMDRJE Executing 2E10 970C The command ends abnormally because the
specified Thin Image pair is not assigned to an S-
VOL.
CMDRJE Executing 2E10 9710 The clone attribute of the specified Thin Image pair
is enabled.
CMDRJE Executing 2E10 9711 The operation cannot be performed because the S-
VOL is the node volume.
CMDRJE Executing 2E10 9713 The operation cannot be performed because the
snapshot tree is being deleted.
CMDRJE Executing 2E11 800F The operation failed because multiple versions of
DKCMAIN microcode are included.
9-108
Troubleshooting
Command Control Interface User and Reference Guide

Table of Contents

Other manuals for Hitachi HUS VM

Related product manuals