EasyManua.ls Logo

Hitachi HUS VM - Page 434

Hitachi HUS VM
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
raidcom replace snapshot
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
migration is specified as the S-VOL of a Thin Image
pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E30 0099 The specified LDEV is a volume of which Data
Direct Mapping attribute is enabled.
CMDRJE Executing 2E30 0201 The specified LDEV is an external volume of which
Data Direct Mapping attribute is enabled.
CMDRJE Executing 2E30 0202 The specified LDEV is a virtual volume of which
Data Direct Mapping attribute is enabled.
CMDRJE Executing 2E31 9701 For replacement of pairs with the cascade or clone
attribute, a Dynamic Provisioning V-VOL is not
specified for the S-VOL.
CMDRJE Executing 2E3F 8000 The specified operation is not supported in the
current microcode version.
CMDRJE Executing B980 B903 The operation cannot be performed because the
selected resource belongs to
NAS_Platform_System_RSG.
Table 9-53 SSB codes returned by raidcom unmap snapshot
raidcom unmap snapshot
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 0028 The command ends abnormally because the
volume whose LDEV number is out of range is
specified as the P-VOL of a Thin Image pair or a
Copy-on-Write Snapshot pair.
CMDRJE Executing 2E00 0029 The command ends abnormally because the
volume whose LDEV number is out of range is
specified as the S-VOL of a Thin Image pair or a
Copy-on-Write Snapshot pair.
CMDRJE Executing 2E10 0028 The command ends abnormally because the
volume other than V-VOL is specified as the S-VOL
of a Thin Image pair or a Copy-on-Write Snapshot
pair.
CMDRJE Executing 2E10 0056 The specified volume cannot be used for the Thin
Image pair operation because the virtual LDEV ID
is deleted.
CMDRJE Executing 2E10 005B The Thin Image pair operation cannot be
performed because the virtual storage machine of
the specified P-VOL is different from the virtual
storage machine of the specified S-VOL.
9-110
Troubleshooting
Command Control Interface User and Reference Guide

Table of Contents

Other manuals for Hitachi HUS VM

Related product manuals