raidcom unmap snapshot
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E21 930A The virtual storage machine with the specified
serial number is not found.
CMDRJE Executing 2E30 008F The command ends abnormally because the
specified P-VOL is not a P-VOL of a Thin Image
pair.
CMDRJE Executing 2E30 0099 The specified LDEV is a volume of which Data
Direct Mapping attribute is enabled.
CMDRJE Executing 2E30 0201 The specified LDEV is an external volume of which
Data Direct Mapping attribute is enabled.
CMDRJE Executing 2E30 0202 The specified LDEV is a virtual volume of which
Data Direct Mapping attribute is enabled.
CMDRJE Executing 2E3F 8000 The specified operation is not supported in the
current microcode version.
CMDRJE Executing B980 B903 The operation cannot be performed because the
selected resource belongs to
NAS_Platform_System_RSG.
Table 9-54 SSB codes returned by raidcom add ssid
raidcom add ssid
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 3001 The CU number of the RCU exceeds the effective
value.
CMDRJE Executing 2E00 3008 The command cannot be executed because the
parameter of the specified RCU is invalid.
CMDRJE Executing 2E00 7100 The CU number is out of effective range.
CMDRJE Executing 2E11 8004 The operation cannot be performed because the
microcode is being changed.
CMDRJE Executing 2E20 3000 The serial number, product ID, or SSID of the
target storage system is incorrect.
CMDRJE Executing 2E20 3001 The command cannot be executed because the
specified RCU is not registered.
CMDRJE Executing 2E22 3002 The operation cannot be performed due to one of
the following reasons:
• The number of RCUs registered in MCU or RCU
is more than four.
• The number of RCUs registered in the system
is more than 64 in the case of specifying the
cu free.
9-112
Troubleshooting
Command Control Interface User and Reference Guide