Remove the front panel.
5
4
Remove the micro mesh stainless filter.
1 Push the end of the right-side arm outward to release the tab.
2 Move the left-side arm outward to release the left tab, and then pull the panel towards you.
Filter locks
Hold this part to pull it out
Slightly lift up the micro mesh stainless filter
and pull it out towards you.
2
1
PUSH
Arm
Arm
Pull the filter locks to the front towards
the direction as illustrat
ed.
6
In the event the micro mesh stainless filter is heavily dirty,
wash the filter with neutral detergent and rinse well with
- 9 -
Wash with water.
Sponge
Micro mesh stainless
water, and then dry the filter in the shade.
7
Attach the micro mesh stainless filter.
8
Attach the front panel.
9
Close the front panel.
10
Turn on the circuit breaker.
Maintenance of Micro Mesh Stainless Filter (continued)
Align the filter with the top face of the indoor unit, and then slide and push it in.
(The shape of the left and right filters is the same.)
Tighten the left and right filter locks to the indicated direction.
1 Insert the shaft of the left arm along the step on the unit into the hole.
2 Securely insert the shaft of the right arm along the step on the unit into the hole.
3 Make sure that the front panel is securely attached.
CAUTION
• Improper installation of the micro mesh stainless !lter could result in malfunction. Filter cleaning
operation can not be performed properly and the indicator blinks.
• Do not operate the air conditioner without the micro mesh stainless !lter.
Dust goes in the gap of the heat exchanger as well as inside the appliance and may cause unpleasant smell
on the heat exchanger or could result in malfunction.
• Be extra careful not to cut your hand with the !n of the heat exchanger when removing and
reattaching the micro mesh stainless !lter.
Pull it downward.
Push the both ends of the front panel first and then its center until it clicks.
CAUTION
If the front panel is loose, it may come off and drop.
When opening the front panel upwards, please do not use excessive force.
If the front panel comes off the device, this may cause it to malfunction.
2
1
ilter locks
Neck
F
4 Attach the temperature display box and WIFI adapter.
Arm
Hole
Arm
Hole
- 10 -
(FILTER CLEAN)
28