5'' 5'' 5''
5'' 5''
1. The product will be considered to have a startup error when the logic of the limit switch has not changed for more than 5 seconds after being started from the initialization side.
2. The product will be considered to have an error when 3 startup errors are finalized.
Limit
switch
Initialization
side
Operation lamp
Cleaning lamp
Power
Product command
Cleaning initiated
Initialization
--> dust box
Dust box -->
initialization
Lit 4 seconds / off 1 second
Cleaning unit
driving motor
5. Automatic operation with the timer stopped
Operation diagram for filter cleaning 4
(remarks)
1. Cleaning in general
(1) If, during cleaning, the remote control is used to start the
air-conditioner by cooling, heating, or other operation,
the cleaning will be stopped at that time. While the product
is being run, the cleaning unit will be returned to its initial
position.
(2) The cumulative count of operating hours will be initialized
only when the cleaning has come to a normal end.
(1) If the air-conditioner auto-fresh holds while the product is
stopped, it will start to clean itself after that operation is over.
2. Automatic cleaning
3. Manual cleaning
(1) This will not be activated during initialization or automatic
cleaning.
4. Forcible cleaning
(1) This will not be activated during,air-conditioner cleaning,or
auto-fresh.
(2) This will not be activated while the sleep timer is on.
(3) This will not be activated for 15 minutes after preheating,
defrost, or preheating cancellation.
(1) The basic mode is the same as normal automatic cleaning.
(2) This will be performed for more than 70 cumulative hours
when stopped by the timer. In the meantime, if normal
automatic, manual, or forcible cleaning holds, the cumulative
70 hours will be initialized.
Operation diagram for filter cleaning (error detection 1)
Startup error
60