13. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations] Erroneous connection in the indoor-outdoor connection line (F cable)
  ・Wire break or poor insertion of the indoor-outdoor connection line (F cable)
 ・Electrical parts in the outdoor unit
 Communication error due to noise in other home electronics
This does not constitute a failure in the air-conditioner.
[Cautions] When lines A and B of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times", then, just in case, check if the F cable is not erroneously connected.
・Detecting this failure mode turns off the power relay 3 minutes later and blocks the power
supply to the outdoor unit.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Ye s
Ye s
Ye s
Ye s
No
No
No
No
Correct the F cable connection.
Is the CN30 securely inserted into
the outdoor board?
Correct the connector.
Press the START/STOP button on the remote control
unit and start the product.
Are terminals A and B of the terminal board of the
electrical parts of the outdoor unit subjected to
220V AC?
Take measurements within 3 minutes after remote
control operation.
Check the electrical parts of the
outdoor unit.
Are terminals A and B of the terminal board of the electrical
parts of the indoor unit subjected to 220V AC?
Take measurements within 3 minutes after remote control
operation.
Double-check the F cable for erroneous connection,
wire break and poor insertion, and correct the
nonconforming parts.
Replace the "indoor electrical parts".
14. Timer lamp blinking: blinking 13 times
[Situation] The timer lamp blinks 13 times and the product will not run.
[Estimated failure location] EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor electrical parts".