SERVICE MANUAL
PRIMAIRY
LARGE SINGLE SPLIT
DC-INVERTER SERIES
MODELS
MODELS
HS2021393HA
SM)-210131
INDOOR UNITS
OUTDOOR UNITS
DUCTED
RPIL-1.0PNN1DH
RPIL-1.5PNN1DH
RPIL-2.0PNN1DH
RPIM-3.0PNN1DH
RPIM-4.0PNN1DH
CASSETTE
RCIM-1.0PNN1DH
RCIM-1.5PNN1DH
RCI-2.0PNN1DH
RCI-3.0PNN1DH
RCI-4.0PNN1DH
RAS-1.0PNNBDH1
RAS-1.5PNNBDH1
RAS-2.0PNNBDH1
RAS-3.0PNNBDH1
RAS-4.0PNNBDH1

Other manuals for Hitachi RAS-2.0PNNBDH1

Questions and Answers

  • M
    monicawagnerAug 9, 2025
    Why is my Hitachi Inverter air conditioner not cooling/heating properly?
    • J
      Jeffrey JohnsonAug 9, 2025
      There are several reasons why your Hitachi Inverter air conditioner might not be cooling or heating effectively. It could be due to a dirty outdoor heat exchanger (like the condenser), heating devices operating indoors, insufficient air tightness in the room, a blockage of the outdoor heat exchanger, or an incorrect temperature setting. To resolve this, try cleaning the outdoor unit's heat exchanger, removing any heating devices, ensuring the room is properly sealed, removing any obstacles blocking the outdoor unit, and verifying that the temperature is set correctly.
  • B
    Bridget HickmanAug 15, 2025
    What to do if my Hitachi Inverter air conditioner won't start up?
    • T
      Tami RoblesAug 15, 2025
      If your Hitachi Inverter air conditioner isn't starting, the issue could stem from several causes. First, check the power supply circuit to ensure it's functioning correctly. Second, measure the insulation resistance to ground to check for any leakage. Third, inspect the power supply circuit for defective contacts or leak current. Fourth, double-check the remote controller settings. Finally, replace the remote controller batteries.
  • A
    Alex JonesAug 21, 2025
    What to do if my Hitachi Inverter air conditioner is leaking water?
    • E
      enunezAug 21, 2025
      If your Hitachi Inverter air conditioner is leaking water, it could be due to a blocked or broken drainage pipe, or the refrigerant pipe joint not being completely sealed. To fix this, try changing the drainage pipe. Also, re-wrap the refrigerant pipe joint to ensure it is tight.
  • J
    Jack PerezAug 27, 2025
    Why does the compressor in my Hitachi Inverter start and stop frequently?
    • S
      Stephen LeeAug 27, 2025
      If the compressor in your Hitachi Inverter is starting and stopping frequently, it's likely that the air inlet or outlet is blocked. Remove any obstacles to resolve this.
  • E
    erikacollinsSep 3, 2025
    Why is my Hitachi Inverter making sounds from deforming parts?
    • G
      Geoffrey ReyesSep 3, 2025
      During the system's starting or stopping, you might hear a sound. This sound is due to the normal deformation of plastic parts. This is not abnormal, and the sound will disappear soon.

Summary

OPTION LIST

Wired Controller Installation and Settings

Installation, parameters, and operation of the wired controller.

Wireless Remote Controller Operation

Functions, modes, and settings of the wireless remote controller.

IR Receiver Installation and Functionality

Guide to installing and using the IR receiver unit.

TROUBLESHOOTING

Malfunction Troubleshooting Guide

Guide for normal malfunctions and initial fault code checks.

Fault Code Analysis and Solutions

Detailed fault codes for indoor and outdoor units with corrective measures.

Driving Board and Limitation Code Analysis

Analysis of driving board faults and operational limitation codes.

COMPONENT CHECKING

Refrigerant System and Parts Check

Procedures for checking refrigerant systems, fan motors, compressor, and fuses.

DISASSEMBLY PROCEDURE

Outdoor Unit Disassembly and Assembly

Steps for disassembling and assembling outdoor units (compressor, motor).

Indoor Unit Fan Motor Replacement

Procedures for removing and replacing fan motors in ducted indoor units.

Cassette Unit Component Replacement

Steps for replacing fan motors and condensate pumps in cassette units.

CONTROL LOGIC DESCRIPTION

Operating Mode Logic

Control logic for Fan Only, Cooling, Heating, and Auto modes.

Protection Modes Logic

Logic for evaporator low-temperature and condenser high-temperature protection.