EasyManua.ls Logo

Hitachi RAS-25CNH2 - Room Temperature Thermistor Circuit; Heat exchanger temperature thermistor circuit

Hitachi RAS-25CNH2
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
5. Room Temperature Thermistor Circuit
Fig. 5-1 shows the room temperature
thermistor circuit.
5
4
3
2
1
0
010
Room temperature (˚C)
Fig. 5-2
20 30 40
0V
Room
temperature
thermistor
0V
5V
Fig. 5-1
3
A
R309
C302
Micro
computer
Room
temp. input
Voltage at
(V)
R310
0V
Heat exchanger
temperature thermistor
0V
5V
Fig. 6-1
4
A
R307
C301
Micro computer
Heat
exchanger
temperature
input
R308
A
5
4
3
2
1
0
010
-10
Heat exchanger temperature (˚C)
Fig. 6-2
20 30 40
Voltage at
(V)A
6. Heat exchanger temperature thermistor circuit
The voltage at A depends on the room
temperature as shown in Fig. 5-2.
The circuit detects the indoor heat
exchanger temperature and controls
the following.
(1) Preheating.
(2) Low-temperature defrosting
during cooling and dehumidifying
operation.
(3) Detection of the reversing valve
non-operation or heat exchanger
temperature thermistor open.
The voltage at A depends on the heat
exchanger temperature as shown in
Fig. 6-2.

Other manuals for Hitachi RAS-25CNH2