EasyManuals Logo

Hitachi RAS-3WHVRP Technical Catalogue

Hitachi RAS-3WHVRP
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
2 General data
Capacity tables
TCGB0123 rev.2 - 10/2019
19
2
YUTAKI M
HP 2.0 HP 3.0 HP
Outdoor unit model RASM-2VRE RASM-3VRE
OAT
(DB/WB)
WIT / WOT - Unit Heating operation
7 / 6 ºC
30 / 35 ºC
CAP (Nom./Max.) kW 1.85 / 4.30 / 6.50 2.1 / 8.00 / 11.0
COP (Nom.) - 5.25 4.60
47 / 55 ºC
CAP (Nom./Max.) kW 4.30 / 6.00 8.00 / 9.50
COP (Nom.) - 3.00 2.80
-7 / -8 ºC
30 / 35 ºC
CAP (Nom./Max.) kW 4.50 / 5.30 5.80 / 7.50
COP (Nom.) -
2.80 2.70
47 / 55 ºC
CAP (Nom./Max.) kW 4.00 / 4.20 5.00 / 5.50
COP (Nom.) - 2.00 1.75
OAT
(DB/WB)
WIT / WOT - Unit
Cooling operation
(Using cooling kit accessory)
35 / -- ºC
12 / 7 ºC
CAP (Nom/Max) kW 4.00 / 5.00 6.50 / 7.00
EER (Nom.) - 4.00 3.35
23 / 18 ºC
CAP (Nom/Max) kW 5.50 / 6.40 7.00 / 9.00
EER (Nom.) - 5.40 5.00

Table of Contents

Other manuals for Hitachi RAS-3WHVRP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-3WHVRP and is the answer not in the manual?

Hitachi RAS-3WHVRP Specifications

General IconGeneral
BrandHitachi
ModelRAS-3WHVRP
CategoryHeat Pump
LanguageEnglish

Related product manuals