EasyManua.ls Logo

Hitachi RAS-50FH5 - Initial Setting Circuit

Hitachi RAS-50FH5
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69
7. Initial Setting Circuit (IC401)
When power is supplied, the microcomputer reads the data in IC401 or IC402 (E
2
PROM) and sets the
preheating activation value and the rating and maximum speed of the compressor, etc. to their initial
values.
Data of self-diagnosis mode is stored in IC401 or IC402; data will not be erased even when power is
turned off.
Fig. 7-1
Microcomputer
External ROM
SCL
SDA
0V
0V
0V
5V
5V 5V
C401
IC401 (E
2
PROM)
404R
304R
27
26
1
2
3
4
8
7
6
5
}

Table of Contents

Related product manuals