14 
A10762290A
● The“ControlCoolAir”functionmaynothave
mucheectdependingontheoperating
conditionsoftheoutdoorunit.
● Incaseoneoutdoorunitisconnectedtomultiple
indoorunitsandtherateoftheseindoorunits
whichareequippedwiththe“ControlCoolAir”
functionislow,thisfunctionmaynothavemuch
ofaneect.
● Whenthisfunctionisset,itmaytakeafew
minutestocooltheentireroom.
● Whilethisfunctionisactivated,“Colddraftrest.”
isdisplayedontheLCDcontrolpanelofthe
wiredcontroller.
10.1.6 AutomaticHeating/CoolingOperation
Incasedualsetpointisselectedinautomatic
heating/coolingoperation,duringautomodeboth
coolingsetpointandheatingsetpointcanbe
selected.
Bydefault,temperaturewhentheheating/cooling
modechangesareasfollows. 
Coolingmodechangestoheatingmodewhenthe
indoortemperatureisheatingsetpoint-1
o
C. 
Heatingmodechangestocoolingmodewhenthe
indoortemperatureiscoolingsetpoint+1
o
C.
Ifthetemperatureforchangingmodesrequires
tobechanged,refertothe“Installation&
MaintenanceManual”forthewiredcontrollerand
the“ServiceManual”fordetails.
Anautomaticheating/coolingoperationrequires
extrasettings.
Refertothe“Installation&MaintenanceManual”
forthewiredcontrollerandthe“ServiceManual”
fordetails.
A/C
MODE SPEED
TEMP
AUTO
Meeting Room
LOUV.
Avoid
HEAT TEMP
Adj.LOUV.
28
.5
26
.5
COOL HEAT
A/C
MODE SPEED
TEMP
AUTO
LOUV. Adj.
Meeting Room
LOUV.
Cold draft rest.
Avoid
28.0
•DierentOperationMode
Whentheoperationmodesetbythewired
controllerisdierentfromtheoutdoorunit
operationmode,theactualoperationmode
ashesontheLCD.
(exceptfortheheatrecoverysystemmodels)
Theabovedisplayshowsthecasethat
thecoolingmodeissetfromthewired
controllerwhileactualoperationmode
oftheoutdoorunitisheating.
Thecurrentoperationmodeandthemessage 
“OtherremoteareinHEATsetting”willbe
ashing.
10.1.5 ColdDraftControlduringCoolingOperation
(1) Function 
Thisfunctioncontrolstheovercoolingairow
topreventofcolddraft.
(2) SettingItems
*OFF :Thisfunctionisnotavailable.
*LOW:
Theover-coolingairow 
 temperatureiscontrolledlowdegree.
*MID :Theover-coolingairow 
 temperatureiscontrolledmedium 
 degree.
*HIGH:Theover-coolingairow 
 temperatureiscontrolledhigh 
 degree.
(Thedefaultsettingis“OFF”)
(3) SupplementofFunction
•Thedischargeairtemperatureiselevated
higherin“HIGH”>“MID”>“LOW”order.
•Therecommendeddischargeair
temperaturesettingis“LOW”. 
(Whenfeelingcoldat“LOW”,changethe
settingto“MID”or“HIGH”.)
*Thisfunctionalsoreducestheformationof
dewcondensationontheindoorunitwhen
thedischargeairtemperatureislowerthan
theinletairtemperatureinaveryhumid
room. 
(Therecommendeddischargeair