Loading...
6
EMERGENCY OPERATION
9
DSW7: Fuse Recover and Remote control
switch system
Not setting is required. Setting position before
shipment is all OFF.
ON
1 2
In case of applying high voltage to the terminal
1,2 of TB1, the fuse on the PCB1(M) is cut.
In such a case, firstly correct the wiring to TB1
and then turn on #1. (as showing beside)
ON
1 2
CAUTION:
Do not turn the air louver by hand. If moved, the
louver mechanism will be damaged! (in all units)
Adjust the vertical deflectors by hand to discharge air in the
required direction.
Do not swing 1 blade at left side and 2 blade at right side of the
vertical deflection.
Automatic Setting of louver:
When the unit operation is stopped, two air louvers are stopped at
closing position automatically.
6. EMERGENCY OPERATION
6.1. OPERATION AND FUNCTION
In case that the unit is required to be operated when the
wireless remote control switch is out of battery and can not
function, etc., the unit can be operated by the emergency
operation switch.
NOTE:
The unit will operate at the following setting.
Automatic COOL/HEAT Operation
Temperature: 25 o C
Fan Speed: High
Swing Louver: Horizontal
RPK-0.8~2.0
Ù
ÙÙ
ÙStep 1
Pull up right and left side of the air intake grille.
Ù
ÙÙ
ÙStep 2
Press the emergency operation switch by using a small
bar or things like that.
Ù
ÙÙ
ÙStep 3
During emergency operation, if pressing the emergency
operation switch again, the unit will be stopped.
RPK-2.5~4.0
Ù
ÙÙ
ÙStep 1
Press the emergency operation switch by using a small
bar or things like that.
Emergency
Operation
Switch
Small Bar
Approx.
7mm
Ù
ÙÙ
ÙStep 2
During emergency operation, if pressing the emergency
operation switch again, the unit will be stopped.
CAUTION:
Do not press the emergency operation switch by
using metals such as a pen or a needle.It will cause a
failure.
Horizontal
Deflector
Vertical
Deflector
A
ir
Filter
Emergency
operation
Switch

Related product manuals