4-8
Chapter 4
For parameter configuration
[dE-01] to [dE-50]
Code/Name
Range (unit)
dE-01 Trip Counter
0 to 65535 times
dE-1120 Trip monitoring
Factor,frequency(±),current,voltage
across P-N,INV status,LAD status,
INV control mode,
restriction status,
sepecial status,
running time,Power-on time
dE-3140
Retry monitoring
Factor,frequency(±),current,voltage
across P-N,INV status,LAD status,
INV control mode,
restriction status,
sepecial status,
running time,Power-on time
dE-50 warning monitor
Refer to the table below.
For more information, contact
your supplier or local Hitachi
inverter sales office.
[FA-01] to [FA-40]
Variable mode monitor (F code)
If a parameter that is being monitored by one of the [FA] parameters
can be modified, it can directly be modified through that [FA]
parameter.
Code/Name
Range (unit)
FA-01
Main speed reference setting or
monitor
0.00 to 590.00(Hz)
FA-02
Sub-speed reference setting or
monitor
-590.00 to 590.000(Hz)
(at monitor)
0.00 to 590.00(Hz)
(at setting)
FA-10
Acceleration time setting or
monitor
0.00 to 3600.00(s)
FA-12
Deceleration time setting or
monitor
FA-15
Torque reference setting or
monitor
-500.0 to 500.0(%)
FA-16
Torque bias setting or monitor
-500.0 to 500.0(%)
FA-20
Position reference setting or
monitor
When
[AA121]≠10 or [AA123]≠03
-268435455 to
+268435455 (pls)
Other than above.
-1073741823 to
+1073741823 (pls)
FA-30
PID1 set-point 1 setting or
monitor
-100.00 to 100.00(%)
(Range will depend on the
[AH-04][AH-05][AH-06] )
FA-32
PID1 set-point 2 setting or
monitor
FA-34
PID1 set-point 3 setting or
monitor
FA-36
PID2 set-point setting or monitor
-100.00 to 100.00(%)
(Range will depend on the
[AJ-04][AJ-05][AJ-06] )
FA-38
PID3 set-point setting or monitor
-100.00 to 100.00(%)
(Range will depend on the
[AJ-24][AJ-25][AJ-26] )
FA-40
PID4 set-point setting or monitor
-100.00 to 100.00(%)
(Range will depend on the
[AJ-44][AJ-45][AJ-46] )
No.
MOP display
1 1st highest frequency <
1st frequency upper
limit limiter
102
2 1st highest frequency <
1st frequency lower
limit limiter
103
3 1st highest frequency < 1st main speed command 106
4 1st highest frequency < 1st auxiliary speed command 107
5 2nd highest frequency <
2nd frequency upper
limit limiter
202
6 2nd highest frequency <
2nd frequency lower
limit limiter
203
7 2nd highest frequency < 2nd main speed command 206
8 2nd highest frequency < 2nd auxiliary speed command 207
Judgment condition