SJ100 Inverter
SJ100 Inverter Specifications
Model-specific tables for 200V and 400V class inverters
The following tables are specific to SJ100 inverters for the 200V and 400V class model
groups. Note that “General Specifications” on page 1–9 apply to both voltage class
groups. Footnotes for all specifications tables follow the table below.
Item 200V Class Specifications
SJ100 inverters,
200V models
CE version 002NFE 004NFE 005NFE 007NFE 011NFE
UL version 002NFU 004NFU 007NFU
Applicable motor size *2 kW 0.2 0.4 0.55 0.75 1.1
HP 1/4 1/2 3/4 1 1.5
Rated capacity
(kVA) *12
230V 0.6 1.0 1.1 1.5 1.9
240V 0.6 1.0 1.2 1.6 2.0
Rated input voltage 1-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,
3-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,
(037LFU, 055LFU, and 075LFU 3phase only)
Rated input
current (A)
1-phase 3.5 5.8 6.7 9.0 11.2
3-phase 2.0 3.4 3.9 5.2 6.5
Rated output voltage *3 3-phase: 200 to 240V (corresponding to input voltage)
Rated output current (A) 1.6 2.6 3.0 4.0 5.0
Efficiency at 100% rated output (%) 90.5 92.8 93.6 94.1 95.4
Watt loss,
approximate (W)
at 70% output 15 21 25 31 38
at 100% output 19 29 32 41 51
Starting torque *6 200% or more
Dynamic braking
approx. %
torque, short
time stop *7
without resistor,
from 50 / 60 Hz
100%: 50Hz
50%: 60Hz
70%: 50Hz
50%: 60Hz
with resistor 150%
DC braking Variable operating frequency, time, and braking force
Weight kg 0.7 0.85 0.85 1.3 1.3
lb 1.54 1.87 1.87 2.87 2.87

Other manuals for Hitachi SJ100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi SJ100 and is the answer not in the manual?

Hitachi SJ100 Specifications

General IconGeneral
SeriesSJ100
Power Range0.4 - 220 kW
Output Frequency0.5-400Hz
Overload Capacity150% for 60 seconds
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Horsepower Range0.5-300HP
CommunicationModbus
Cooling MethodFan-cooled
Communication InterfaceRS485
Operating Temperature-10°C to +50°C
Storage Temperature-20 to +60°C (-4 to 140°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Output Voltage3-Phase 0-480VAC (matching input voltage)