What to do if Hitachi YUTAKI S80 RWH-6.0VNFE Air Conditioner has Receiver Communication failure?
- AAmanda ThomasAug 31, 2025
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.

What to do if Hitachi YUTAKI S80 RWH-6.0VNFE Air Conditioner has Receiver Communication failure?
If your Hitachi Air Conditioner is not receiving a signal, check the Opentherm/Hlink connection.
What to do if Hitachi YUTAKI S80 RWH-6.0VNFE shows abnormal transmission between outdoor and indoor units?
If your Hitachi Air Conditioner shows 'Abnormal transmission between outdoor and indoor units', check the wiring, terminals, and PCB for faults. This issue can be caused by incorrect wiring, loose terminals, PCB failure, a tripped fuse, or the power supply being OFF.
Why does my Hitachi Air Conditioner activate safety device from excessively high discharge pressure?
If your Hitachi Air Conditioner activates the safety device due to excessively high discharge pressure, inspect the heat exchanger and refrigerant conditions. This activation can be caused by overload (obstruction of HEX, short circuit), a mixture of inert gas, or excessive refrigerant.
What causes Hitachi YUTAKI S80 RWH-6.0VNFE to activate safety device from excessively low suction pressure?
If your Hitachi Air Conditioner activates the safety device from excessively low suction pressure, inspect refrigerant levels and piping for blockages. This issue is often due to a shortage or leakage of refrigerant, piping clogging, a closed expansion valve, or a locked fan motor.
How to troubleshoot Hitachi Air Conditioner hydraulic alarm flow and water pump malfunction?
If your Hitachi Air Conditioner displays a hydraulic alarm related to flow and water pump malfunction, check the water pump for proper operation and repair or replace it if defective. This alarm indicates that water flow is not detected in the hydraulic cycle or the pump is defective.
What to do if Hitachi YUTAKI S80 RWH-6.0VNFE shows Thermostat Heater Alarm?
If your Hitachi Air Conditioner is showing a high temperature in the electric heater, check the electric heater for proper operation.
How to fix Hitachi YUTAKI S80 RWH-6.0VNFE activation of overcurrent protection?
If your Hitachi Air Conditioner activates overcurrent protection, inspect the inverter PCB and compressor operation. This can be caused by overload, overcurrent, failure of the Inverter PCB, a clogged heat exchanger, a locked compressor, or EVI/EVO failure.
How do I fix a 'Unit Capacity setting Error' on my Hitachi YUTAKI S80 RWH-6.0VNFE Air Conditioner?
If your Hitachi Air Conditioner displays a 'Unit Capacity setting Error', ensure correct capacity settings for both indoor and outdoor units. This error indicates a mismatch between the indoor and outdoor unit capacities.
How to correct Hitachi YUTAKI S80 RWH-6.0VNFE Air Conditioner incorrect indoor unit number setting?
If your Hitachi Air Conditioner displays 'Incorrect indoor unit number setting', correct the indoor unit number settings. This issue can be caused by duplication of indoor unit numbers or the number of indoor units exceeding specifications.
How to fix Incorrect PCB Setting in Hitachi YUTAKI S80 RWH-6.0VNFE Air Conditioner?
If your Hitachi Air Conditioner shows 'Incorrect PCB Setting', correct the DSW settings. This issue is caused by a wrong DSW setting in the case of Co041.
| Brand | Hitachi |
|---|---|
| Model | YUTAKI S80 RWH-6.0VNFE |
| Category | Air Conditioner |
| Language | English |
Provides crucial safety precautions and warnings for handling and operating the heat pump system.
Specifies wiring size requirements for outdoor and indoor units based on current and cable types.
Details the location of DIP and rotary switches on the outdoor unit's PCB for configuration.
Illustrates main power supply and indoor/outdoor communication wiring connections.
Details input and output terminal connections for PC-ARFHE, 4-20mA, sensors, and valves.
Guides the user through initial system configuration based on installation type and components.
Details the procedure for purging air from the system, including duration and start command.
Guides through the unit test run process, specifying duration, mode, and start command.
Lists alarm codes displayed on the remote control switch and their detailed abnormalities.