A2 VFD (0.75-30kW)
12
Chapter 7 Description of Configure Parameters
Pn 01 Default display content1——30000
RUN 1 means it will display runtime frequency
Otherwise, it displays motor’s synchronization speed. 2
——
30000 is motor synchronization speed
STOP
it will display frequency given by external signal.
Pn 02 Initial startup frequency by panel or other method Range
000.01Hz400.00Hzthe initial panel data and
external signal frequency during startup.
Pn 03 Source of runtime frequency with range1—7
1 Potentiometer 2 Panel button
3 External 0-5V signal 4 External 0-10V signal
5 External 0-20mA signal 6 External digital signal
7 Multi-segment signal
Pn 04 Source of runtime command with range
1—2
1 Panel button control 2 External signal control
Pn 05 clockwise / anticlockwise disable with range
1—3
1 clockwise enable only 2 anticlockwise enable only
3 clockwise / anticlockwise enable
Pn 06 Method to stop VFD with range1—2
1 stop by itself 2 stop by deceleration
Pn 07 Start again by external signal with range
1—2
1 disable 2 enable
Description: when the power on the external operation of
the signal is allowed to start effectively.
Pn 08 Acceleration time with range000.01S650.00S
Accelerate time (from 0Hz to Pn10).