A2 VFD (0.75-30kW)
13
Pn 09 Deceleration time with range
000.01S
650.00S
Decelerate time (from Pn10 to 0Hz).
Pn 10 Maximum runtime frequency with range
000.10Hz
400.00Hz
Maximum output frequency by VFD.
Pn 11 Minimum runtime frequency with range000.10Hz400.00Hz
If the frequency from command below this value, VFD
will stop. It wouldn’t recover until command frequency up
this value.
Pn 12 Motor rating frequency with range010.00Hz400.00Hz
It is used for modify the V/Fcurve.
Pn 13 Torque compensation with range0.0—4.0
Large parameter may cause damage to the motor.
Pn14 Torque compensation frequency
0.01Hz—400.00.00Hz VFD
doesn’t provide torque compensation if runtime
frequency is larger than this value.