A2 VFD (0.75-30kW)
14
Pn 15 Startup DC braking voltage
1V—100V
By proper tuning of this parameter, motor can start
normally from fully stop state without any difficult caused
by motor’s free motion and rotate direction.
Pn 16 Startup DC braking time000.00S—650.00S
DC braking time before motor startup to ensure that motor
is started from fully stop state.
Pn 17 Stop DC braking voltage
1V—100V
Braking voltage during DC braking period to ensure that
motor is fully stopped in brake time.
Pn 18 Stop DC braking time000.00S—650.00S
DC braking time to prevent the slide move after stopping.
Pn 19 Source of multi-segment speed 01—5
Multi-segment speed mode 0-segment frequency source
1 Potentiometer 2 Panel button
3 External 0-5V signal 4 External 0-10V signal
5 External 0-20mA signal
Pn 20 Multi-segment speed 1 frequency000.10 Hz—400.00Hz
Multi-segment speed mode 1-segment frequency
Pn 21 Multi-segment speed 2 frequency000.10 Hz—400.00Hz
Multi-segment speed mode 2-segment frequency
Pn 22 Multi-segment speed 3 frequency000.10 Hz—400.00Hz
Multi-segment speed mode 3-segment frequency