Pn 23 Multi-segment speed 4 frequency
:
000.10 Hz—400.00Hz
Multi-segment speed mode 4-segment frequency
Pn 24 Multi-segment speed 5 frequency:000.10 Hz—400.00Hz
Multi-segment speed mode 5-segment frequency
Pn 25 Multi-segment speed 6 frequency:000.10 Hz—400.00Hz
Multi-segment speed mode 6-segment frequency
Pn 26 Multi-segment speed 7 frequency:000.10 Hz—400.00Hz
Multi-segment speed mode 7-segment frequency
Pn 27 Point move frequency
:
000.10 Hz—400.00Hz
Point move frequency
Pn 28 Choice of relay output
:
1—6
1 Stop VFD 2 Run VFD
3 VFD fault 4 Frequency increasing
5 Frequency decreasing 6 Frequency reached
If output condition is satisfied, ON/OFF states reverse.
Pn 29 2rd acceleration time
:
000.01S
-
650.00S
2rd acceleration time
Pn 30 2rd deceleration time
:
000.01S
-
650.00S
2rd deceleration time
Pn 31 2rd deceleration stop frequency
:
000.10 Hz—400.00Hz
When runtime frequency is larger than this value,
acceleration/deceleration time is defined by Pn08,Pn09
When runtime frequency is smaller than this value,
acceleration/deceleration time is defined by Pn29,Pn30
As shown in Figure: