The slideways (Fig. 6) should be lubricated once each month. Remove the apron (secured by four
thumb screws) from the front of the pedestal. Lightly coat both slideways with Lubriplate 630AA
(supplied). Replace the apron and thumbscrews.
Fig. 6
TROUBLESHOOTING
SYMPTOMS POSSIBLE CAUSES
Mixer will not start. 1. Gear shift lever between gears (not fully engaged).
2. Circuit protector in open position — check fuse or
disconnect switch.
3. Mixer or attachment overloaded.
4. Bowl not all the way up.
5. Wire Cage Assembly is not in the front-center
position.
SERVICE
If service is needed on this equipment, contact your local Hobart Service Office.