8 Features and Specifications
HP-327 HIT-4U
2.1 General
Display: LCD, updated every 1 seconds.
Total: 8 digits 3/8" high. Resettable using a magnet, a
dry contact, from front panel keypad or via
Modbus communications.
Value is stored in non-volatile memory when
pressing button.
Total Units: GAL, LIT, FT3, ACF, ACFx1000, M3, BBL, KG,
LB, NM3, SCF, SCFx1000.
Grand Total: 8 digits 3/8" high, non-resettable. Value is stored
in non-volatile memory when pressing button.
Grand Total is displayed for 7 seconds after
pressing the
button.
Rate: 6 digits 1/2" high.
Rate Units: /SEC, /MIN, /HR, /DAY
K-factor: The pulses per unit of Total (e.g. pulses/gallon)
are configurable in the range 0.001 to 9,999,999.
Linearization: 2-20 points.
Decimal Points: Decimal Point positions are configurable for 0,
0.0, 0.00, or 0.000 for rate, total and K-factor.
Accuracy: Total and Rate: 0.01% of reading, 1 Count
Flow-Tech, Inc. | In MD 410-666-3200 - In VA 804-752-3450 | www.flowtechonline.com