Table of Contents

Questions and Answers

  • R
    Rhonda PierceAug 1, 2025
    What to do if Holmatro Water Pump tool is not operating?
    • M
      Megan JenkinsAug 1, 2025
      If your Holmatro Water Pump tool isn't operating correctly, consider these potential causes and solutions: * Ensure all couplers are properly connected by disconnecting and reconnecting them. * Verify the pressure relief valve on the pump is in the closed (1) position. * Place the pump horizontally to ensure it is level. * Check the oil level and replenish if necessary, after setting all tools in the output position. * Vent the oil tank if the oil is foaming. * Avoid exceeding the maximum load for the tool. * If the plunger is seized, have it repaired by a Holmatro Certified Technician.
  • C
    christinefischerAug 5, 2025
    Why do Holmatro Water Pump couplers not connect or disconnect?
    • B
      Brittany RobbinsAug 5, 2025
      If the couplers on your Holmatro Water Pump are not connecting or disconnecting, here are a few things to check: * Clean the couplers if they are dirty. * Release any pressure in the tool or hose using the pressure relief tool. This pressure can build up from temperature changes during storage or transport. * Ensure the couplers are aligned properly when connecting; press them together smoothly. * Support and guide the male coupler during disconnection. * Check and clean the snap ring on the female coupler for any blockage. * If the female coupler is faulty, have it replaced by a Holmatro Certified Technician.
  • J
    jennifer13Aug 9, 2025
    What to do if Holmatro PA Water Pump leaks oil?
    • D
      Daniel BrownAug 9, 2025
      If your Holmatro Water Pump is leaking oil, check the following: * Ensure that the oil level is not too high. If it is, bring the oil level back to the correct level after setting all tools in the starting position. * Make sure the couplers are correctly connected and tighten any loose couplers.
  • K
    Karen NelsonAug 14, 2025
    Why Holmatro PA couplers do not stay connected?
    • S
      sherrywheelerAug 14, 2025
      If the couplers on your Holmatro Water Pump aren't staying connected, try the following: * Hold the hose at the bending restriction while connecting if the external ring jams. * Clean the female coupler with clean running water if the locking mechanism isn't working. * Dry the coupler and treat the inside of the external ring with preservative oil. * Repeatedly place and remove the dust cap until the external ring springs back. * If the female coupler is faulty, have it replaced by a Holmatro Certified Technician.
  • M
    Michael StevensAug 19, 2025
    What to do if Holmatro PA Water Pump plunger does not retract?
    • B
      Benjamin JonesAug 19, 2025
      If the plunger of your Holmatro Water Pump's hydraulic tool does not retract, or retracts slower than normal, consider these solutions: * Depressurize the system by setting the pressure relief valve to the open (0) position. * Vent the hydraulic system to remove any air. * If the cylinder return spring is broken or there's other damage to the cylinder, contact your Holmatro dealer.
  • R
    rachelwilliamsAug 23, 2025
    Why does Holmatro PA Water Pump flow drop and lever move back?
    • M
      Matthew WelchAug 23, 2025
      If the flow of your Holmatro Water Pump drops and the lever tends to move back to the tank, it may be due to high vacuum in the tank. Open and close the filler cap to aerate the tank.
  • N
    nflemingAug 27, 2025
    Why does Holmatro PA Water Pump rod move upwards when there is pressure?
    • K
      Kristine BrownAug 27, 2025
      If the pump rod on your Holmatro Water Pump moves upwards when there is pressure, the check valve may be faulty. Have it repaired by a Holmatro Certified Technician.

Summary

Introduction

Disclaimer

Legal notice regarding rights, modifications, and liability for the user manual.

About this manual

States that original instructions are in English and other versions are translations.

Definitions

Defines key terms used in the manual such as System, Pump, Hose, Tool, and Equipment.

General Information

Provides congratulations and general instructions on operation, maintenance, and safety.

Application

Describes the hand or foot pumps as one- or two-stage plunger pumps for driving hydraulic tools.

System Requirements

Outlines compatibility requirements for Holmatro pumps, hoses, and tools.

Life Span and Workability

Discusses how product life span and workability depend on circumstances like usage and load.

Qualified Personnel

States that only trained personnel may operate the system and specifies requirements for repair work.

Guarantee

Refers to general terms for guarantee conditions and lists circumstances that can void the warranty.

Declaration of Conformity

Confirms CE certification and compliance with essential safety requirements.

Safety Regulations

Explanation of Symbols

Explains the meaning of DANGER, WARNING, Caution, and Note symbols used in the manual.

Model Plate and CE Marking

Details the information found on the model plate and CE marking, and associated part numbers.

Personal Safety

Specifies required personal protective equipment (PPE) such as helmets, goggles, gloves, and safety shoes.

Equipment Safety Regulations

Advises against changing settings of safety valves and change-over valves.

System Operation Safety

Outlines safety measures for system operation, including risk assessment, work area, and equipment checks.

Maintenance Safety Regulations

Covers safety precautions for maintenance, including PPE and securing equipment against unexpected activation.

Description

Equipment Overview

Describes the hand or foot pumps for single/double-acting hydraulic tools, mentioning pressure limits and oil volume.

Type Designation

Explains the coding system for pump type designation with an example (PAX 18 H 2).

Product Identification

Lists components identified by numbers in figures, such as pump lever, pressure relief valve, and couplers.

Weight and Dimensions

Provides a table listing models, part numbers, weight, and dimensions (length, width, height).

Technical Specifications

Lists key specifications like operating pressure, required force, pump delivery, oil type, temperature range, and directives.

Preparation for First Use

General Preparation

Instructs to check equipment for completeness and damage, and verify the correct pressure relief tool.

Operation

System Operation Overview

Explains how oil is drawn and pressed into the hose system, and the function of the safety valve.

Coupler Types and Connection

Describes High-Flow and Quick-Lock couplers and their connection procedures.

Pressure Relief Valve Operation

Explains the function and operation of the pressure relief valve for controlled load lowering.

Connecting Hydraulic Hoses

Provides instructions and warnings for connecting hydraulic hoses, including High-Flow and Quick-Lock types.

Disconnecting Hydraulic Hoses

Provides instructions and warnings for disconnecting hydraulic hoses, including High-Flow and Quick-Lock types.

Relieving Pressure in Unconnected Hoses;Tools

Explains how to use the pressure relief tool to remove overpressure in unconnected hoses or tools.

Use

General Use Instructions

Instructs to check equipment for completeness and damage before use.

Before Use Checks

Details pre-use checks including oil level, pump placement, and connecting hydraulic hoses.

During Use

Explains how to unlock the pump lever, set the pressure relief valve, and operate the pump lever.

After Use Procedures

Details shutdown and disconnection procedures after completing the operation.

Post-Use Inspection

Instructs to check the pump for completeness, leaks, and damage after use.

Cleaning and Storage

Provides instructions for cleaning, drying, preserving, and storing the pump after use.

Troubleshooting

General Troubleshooting Advice

Advises consulting the Holmatro dealer for unresolved issues and specifying model/serial number.

Troubleshooting Table

A table listing common problems, their possible causes, and suggested solutions for coupler issues.

Maintenance

General Maintenance

Emphasizes proper preventive maintenance for operational safety and equipment life extension.

Dangerous Substances Warning

Warns about proper collection and disposal of used or leaked fluids and products.

Maintenance Materials

Lists recommended maintenance materials like WD-40, Tectyl ML, and hydraulic oil with their applications.

Maintenance Schedule

Provides an average schedule for general checks, hydraulic couplers, hoses, and oil based on usage intervals.

Maintenance Activities

Details specific maintenance tasks for the pump, hydraulic couplers, dust caps, and hoses.

Hydraulic Oil Check and Refill

Provides step-by-step instructions for checking and refilling the hydraulic oil level.

Oil Tank Venting

Explains how to vent the oil tank to resolve jerky equipment movement caused by air bubbles.

Yearly Dealer Maintenance

Recommends annual inspection, check, setting, and testing by a Holmatro Certified Technician.

Long Term Storage

Provides guidance on ensuring the equipment is depressurized and storing it in a dry, well-ventilated area.

Decommissioning and Recycling

Decommissioning and Recycling Procedures

Outlines steps for decommissioning, ensuring safety, and environmentally responsible recycling of the equipment.

Holmatro PA Series Specifications

General IconGeneral
BrandHolmatro
ModelPA Series
CategoryWater Pump
LanguageEnglish

Related product manuals