6. Swing
Press this button to set swing.
Notice:
Each mode working principle
* mode:
1. The up centrifugal fan will run at low speed ,and the speed cant be adjusted.
2. The compressor and the down centrifugal fan will stop after running 8 mins,
then run again after 6mins.
3. The unit adopts constant temperature dehumidifying mode, and the adjustment
of temperature is no eective.
* mode:
1. When the room temperature is higher than set temperature, the compressor
starts to run.
2. When the room temperature is lower than set temperature, the compressor stop
and operate at original set speed.
* mode:
1. The up centrifugal fan runs at set speed , and the compressor does not run .
2. The adjustment of temperature is no eective.
● Operation
1. Press “Timer” button to set Automatic Off time while the unit is running.
2. Press “Timer” button to set Automatic On time while the unit is ready.
3. The time can be adjusted within a range of 1 hour to 24 hour. Press the temp
up( +) or temp down(- ) button to increase or decrease the time 1 hour by
pressing once.
● Operation
1. The operation is eective when the unit is under mode.
2. Press the button in mode, then the unit will work under sleep mode and
the up centrifugal fan will turn to low speed automatically. The set temperature
O O
will increase 1 C after one hour, and increase 2 C the unit will stop running.
● Operation
1. When the swing button is activated ,the swing blade swings up and down
automatically . If you want to stop, press the button again.