7
disconnect couplings and in
good condition. Before using
the recovery machine, check
that it is in satisfactory
working order, has been
properly maintained and that
any associated electrical
components are sealed to
prevent ignition in the event of
a refrigerant release. Consult
manufacturer if in doubt.
• The recovered refrigerant
shall be returned to the
refrigerant supplier in the
correct recovery cylinder, and
the relevant Waste Transfer
Note arranged. Do not mix
refrigerants in recovery units
and especially not in
cylinders.
• If compressors or compressor
oils are to be removed, ensure
that they have been
evacuated to an acceptable
level to make certain that
flammable refrigerant does
not remain within the
lubricant.
The evacuation process shall
be carried out prior to
returning the compressor to
the suppliers. Only electric
heating to the compressor
body shall be employed to
accelerate this process.
When oil is drained from a
system, it shall be carried out
safely.
• Service shall only be
performed as recommended
by the equipment
manufacturer. Maintenance
and repair operations
requiring the assistance of
other skilled personnel shall
be carried out under the
supervision of the person
competent in the use of
flammable refrigerants.
• Any person who is involved
with working on or breaking
into a refrigerant circuit
should hold a current valid
certificatefrom an industry-
accredited assessment
authority, which authorises
their competence to handle
refrigerants safely in
accordance with an industry
recongnised assessment
specification.
• Please note this product has
non serviceable parts. The
coolant gas in this appliance
cannot be replaced / regased.
• This appliance can be used by
children aged from 8 years
and above and persons with
reduced physical, sensory or
mental capabilities or lack of
experience and knowledge if
they have been given
supervision or instruction
concerning use of the
appliance in a safe way and
understand the hazards
involved.