OPERATION
42
4. Turn on the appliance.
If the generators are overloaded (see page 40), or if there is a short circuit in a
connected appliance, the overload alarm (red) will go ON. The overload alarm
(red) will stay ON, and after about four seconds, current to the connected
appliance(s) will shut off, and the output indicator (green) will go OFF. Stop the
engines and investigate the problem.
Determine if the cause is a short circuit in a connected appliance, an overload,
or an overheated inverter. Correct the problem and restart the generator.
AC Parallel Operation Applications
Follow the instructions included with the parallel operation cable kit.
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. A faulty appliance or power cord
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
• Never connect different generator models and types.
• Use only a Honda approved parallel operation kit (optional equipment) when
connecting two EU3000is generators for parallel operation.
• Never connect or remove the parallel operation kit when the generator is
running.
• For single generator operation, the parallel operation kit must be removed.