SERVICING YOUR GENERATOR
51
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Open and remove the oil maintenance cover.
2. Place a suitable container below the engine to catch the oil, then remove the
drain plug and sealing washer, remove the oil filler cap, and drain the oil.
3. Reinstall the oil drain plug and a new sealing washer. Tighten the plug
securely.
Torque: 13.0 lbf·ft (17.7 N·m, 1.8 kgf·m)
4. With the generator in a level position, fill with the recommended oil to the
upper limit. Do not overfill.
“Upper limit” means the oil exists to the oil filler neck.
Refer to "ENGINE OIL RECOMMENDATIONS" in page 12.
Maximum oil capacity: 18 oz (0.55 L)
5. Reinstall the oil filler cap and tighten it securely.
6. Reinstall, close, and latch the oil maintenance cover.
Wash your hands with soap and water after handling used oil.
OIL MAINTENANCE
COVER
OIL FILLER CAP
OIL DRAIN PLUG
UPPER LIMIT
(The oil exists to the
oil filler neck.)
31ZS96101.book 51 ージ 020年2月26日 水曜日 午後2時33分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU3000is and is the answer not in the manual?

Honda EU3000is Specifications

General IconGeneral
EngineHonda GX200
Displacement196cc
AC Voltage120V
AC Current23.3A
Fuel Tank Capacity3.4 gallons
Run Time at Rated Load7.1 hours
Run Time at 1/4 Load20 hours
Dimensions (L x W x H)25.9" x 17.6" x 22.0"
Dry Weight131 lbs
Rated Output2800W
DC Output12V, 12A
Starting SystemRecoil/Electric
Noise Level49-58 dBA
Maximum Output3000W

Related product manuals