63
Battery charging
(ETS, EWS)
BATTERY
BATTERY HOLDER NUT (2)
POSITIVE ( )
CABLE
NEGATIVE ( )
CABLE
NEGATIVE ( )
TERMINAL
POSITIVE ( )
TERMINAL
BATTERY
BATTERY
FILLER
CAPS
BATTERY CHARGER
NEGATIVE ( ) CABLE
BATTERY CHARGER
POSITIVE ( ) CABLE
Battery charger which is commercially availlablae for 12 V batteries
canbeusedtochargethebattery:
Battery service
If the snowblower will be stored for an extended period, remove the
battery and store in a cool, dry place with the negative terminal
disconnected from the battery. Recharge it every 6 months.
Check the battery electrolyte level (see page ).
Remove the negative ( ) cable from the battery negative ( )
terminal; then remove the positive ( ) cable from the battery
positive ( ) terminal.
Loosen the battery holder nuts and remove the battery.
Remove the battery filler caps, and connect the battery charger
positive ( ) cable to the battery positive ( ) terminal; then
connect the battery charger negative ( ) cable to the battery
negative ( ) terminal.
Charge the battery: 5 10 hours at 1.2 A.
Install the battery in the reverse order of removal.