2
Set the control in Programming Mode and when
prompted:
1. Pull the battery tab to activate the PROSiXFLOOD.
(Use the tamper switch if the battery tab is removed.)
2. The LED flashes (up to about 20 seconds*) during
enrollment.
• The device sends its unique MAC ID (Serial
Number); the controller registers the device and
displays the transmitter data on screen.
*NOTE: Enrollment time varies depending on the
signal strength between the device and the
controller.
3. When done, the LED is ON for 3 seconds and the
control beeps to confirm enrollment.
NOTE: If the device is not successfully enrolled
during the enrollment period, the LED turns off
and the device powers down. Activate the
tamper switch to restart the enrollment
process.
IMPORTANT: Once enrolled in a system, the
PROSiXFLOOD cannot be used with another controller
until it is removed from the current controller. See the
Controller’s instructions for details.
TESTING NOTE: After enrollment, the unit can be tested
by placing the probe in a cup of water. The control should
indicate a fault condition after 15 seconds.
24-HOUR ENROLLMENT DELETION AND
DEFAULT
If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from
the unintended panel, reset the device to factory
default setting:
1. Open the cover and remove the battery.
2. Hold down the tamper switch while reinserting the
battery. Rapid LED flashing indicates successful
deletion (LED flashes as if in enrollment mode). If
LED does not flash, delete was not successful.
3. Reattach the cover.
This procedure is available for 24 hours after
enrollment with a panel and the device remains
powered (battery installed).