IP/GSM Diagnostic Commands (continued)
[E]
PriRSSI 3/4G REG
-xxxdbm stat x
or
PriRSSI 2G REG
-xxxdbm stat x
2G Network Stat can be :
Good 20 to 89 dBm
OK 90 to 98 dBm
Marg. 99 to 104 dBm
Bad 105 to 150
dBm
GSM Status Displays
Only if GSM or IP/GSM
enabled.
PriRSSI – Primary Site
RSSI level in dbm
3/4G – Communicator is on
the 3G/4G network where
“stat” can be:
Good RSSI 20 to 90 dBm
OK RSSI 91 to 99 dBm
Marginal RSSI 100 to 105 dBm
Bad RSSI 106 to 150 dBm
REG – Registration status
from GSM module where
“x” can be:
N – Not Registered
H – Registered Home
S – Searching
D – Registration Denied
R – Registered Roaming
? – Unknown Reg. State
[] to continue to next
screen.
RAT EC/NO
3/4G -xxxxx
RAT = Radio Access
Technology
EC/NO = Carrier Noise
Ratio
(EC/NO does not
apply to 2G network ;
displays N/A)
[] to continue to next
screen.
Cntry Netw LAC
xxx xxx xxxxx
Cntry – Country Code
Netw – Network Code
LAC – Reg. status from
GSM.
[] to continue to next
screen.
Cell BaseSt Chan
Xxxxx x xxx
Cell – Base Station ID
BaseSt – Base Station
Antenna Sector
Chan – Control Channel
in use
[] to continue to next
screen.
Second Site RSSI
-xxxdbm
Secondary GSM Site RSSI
level in dbm.
[] to continue to next
screen.
[F]
Testing Gateway
Redir 1
Network Diagnostic
Test
Only if IP or IP/GSM
enabled.
Performs a set of network
diagnostics that tests the
integrity of the links
between the IP/GSM and
the various connection
points (Redirs) to
AlarmNet.
Key Prompt Function
[S]
FLT
OK
Status request
OK = normal
i = IP off line
I = IP fault reported
g = GSM off line
G = GSM fault reported
[T]
Test Msg Sent
Test Alarm
Sends a Test alarm to
AlarmNet. Functional for a
registered IP/GSM only. If
the device is not
registered, a message is
displayed indicating that
the command cannot be
executed.
[X]
Reset CPU Y/N
Reset the IP/GSM.
[N] = return to diagnostic
mode (blank screen =
enter next command
or escape).
[Y] = resets the module
(blank screen = when
reset complete, enter
next command or
escape).
[
]
Registering
Registration
(Shift-UP arrow)
Registers a programmed
IP/GSM with AlarmNet. If
it is configured to report to
AlarmNet, the IP/GSM will
register with AlarmNet.
[
]
Enter PIN#
Registration with PIN
for Replacement
Module (DN arrow)
Registers a programmed
IP/GSM with AlarmNet if
it is configured to report to
AlarmNet.
[0]
Force Server Update
Y/N
Force Upload of
Configuration File to
Server
[Y] = force the device to
upload its entire
configuration file to the
server.
[N] = cancel the operation.
NOTE: If the internet is
not available, and the
module is not initialized
when you enter this
command, the following
screen will be displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to
light, indicating the
module has completed its
initialization, and try
again.