SMB System C Handling
The Safety Post can be set lower by removing
of pin 100122 and removing Cloxy and push-
ing the post down.
When using Cast-In Sleeves, the length of the
Sleeve must be set so that the Safety Post or
the Safety Post Extender is inserted at least
100 mm into the concrete.
The Plastic Plug in the bottom of the Cast-In
Sleeve reduces the insertion depth and must
be taken into consideration when calculating
the sleeve length.
When inserted in Pre-Cast Attachments,
check that the Safety Post or the Safety Post
Extender is inserted at least 100 mm into the
attachment metal sleeve, unless stated other-
wise in product specific information.
Steel Mesh Barrier Holder 3222
1. Thread the Steel Mesh Barrier Holder onto the
top section of the Safety Post.