Mark V and Mark VII EGPWS Pilot’s Guide
060-4241-000 Smart Runway
®
Rev H, August 2011 71
RAAS Quick
Reference
Continued
34L 16R
34R
16L
11
29
“Approaching Three-Four Right,
Three-Thousand Feet Available”
Approaching Short Runway – In Air
Approach
Conditions for advisory:
· All Approaching Runway – In Air criteria
· Runway length is less than nominal
landing runway length
Operator defined nominal runway length
in metres or feet, RCD option to
annunciate unit of measurement selected
Example in feet
34L 16R
34R
16L
11
29
“Approaching Three-Four Right,
Three-Thousand Available”
“Caution Short Runway, Short Runway”
Approaching Runway – In Air / Caution
Approach
Conditions for caution:
· All conditions for a non-routine
Approaching Short Runway – In Air are
satisfied; and
· Aligned runway is shorter than a nominal
length; and
· Aircraft is between 450 and 300 feet AFE.