Mark V and Mark VII EGPWS Pilot’s Guide
060-4241-000 Smart Runway
®
Rev H, August 2011 73
RAAS Quick
Reference
Continued
34L
34R
16L
29
Runway End
Landing
Conditions for advisory:
· Aircraft on a runway
· Within 20 deg. Of runway heading
· 100 feet (or 30 m) of runway remaining
· Groundspeed below 40 kts
Operator defined units in metres or feet,
confirm units using EGPWS self-test
“100 Remaining”
Example in feet
16R
11
34L 16R
34R
16L
11
29
“On Runway Three-Four Left”
“Flaps, Flaps”
Take-off Flap Monitor
Runway Entry
Conditions for advisory:
· Aircraft enters onto a runway
· Within 20 deg. Of runway heading
· Flap handle not in a valid takeoff
flap setting