Galaxy 2 Series Off - Wall
Tamper Microswitch
Installation Instructions
Install the Off-wall Tamper Microswitch to a G2 Panel
This pack contains the Off-wall Tamper Microswitch and two connecting wires.
There are two methods of installing and wiring the Off-wall Tamper Microswitch to a G2 panel.
Method 1: Wired directly into a zone.
Method 2: Wired using the Deep Discharge Protection Board.
Method 1 – Wired into a Zone
1. Insert the off-wall tamper microswitch with the two connecting wires from the rear of
the panel and clip into position.
2. Connect the two wires from the Off-wall Tamper Microswitch to an unused zone.
NOTE: The wiring shown is for a Normal Closed configuration. For Double-Balanced
and End-of-Line configurations, use a 1k ohm resistor connected in series with
the connecting wires.