23
• Group Choice
Users can be allocated to more than one group, but also have the
choice of which of the allocated groups to view, set or unset.
Pressing * key while assigning groups to the user assigns the
group choice feature.
Notes: 1.The manager has fixed access to all system groups. This
cannot be reprogrammed.
2.The manager is assigned group choice by default, but the
feature can be removed.
3.Users authorised to access the Codes option can only assign
groups that have been assigned to their user code. A user
who does not have access to group 4, cannot assign group 4
to another user code.
Max Number
Each MAX card/tag/fob has a unique 10 digit number laser etched onto
it. A MAX card/tag/fob is assigned to a user by entering this number in
the Max No option. The number identifies the MAX card/tag/fob to
the system and references it to the user it has been assigned to.
1. Enter the unique 10 digit number which is laser etched onto the
MAX card or enter the unique RF keyfob button identifier generated
by the RF RIO or press the A and 1 keys simultaneously of the
KeyProx and present the card/fob to the KeyProx reader
within 5 seconds. The decrypted number in the card will be self
learned onto the Galaxy panel and is displayed on the KeyProx..
2. Press the ent key to save the programming and return to the
previous menu.
Note: A MAX number can be assigned to a user code that does not
have a PIN allocated to it. All other options for this user are valid for
the MAX card/tag/fob. It is recommended that MAX numbers should
be assigned to users not requiring a PIN at the Max Users menu op-
tion.
When a MAX number has been assigned to a user number, a lower case
(m) is displayed on the top line of the user number details screen.
A # assigned to the max number makes the max function dual focus, ie
it needs the pin entered first. A star * assigned to the max number makes
the card dual access, ie it needs another card to open doors.
ent
*
Groups B 1_______
Ú
23_____>B
8
8 = CODES
[ent] to Select
PIN + ent
ent
CODES
1 = User Codes
ent
[ent] to Select
1 = Modify PIN
ent
MAX No
>
001 USER
L3 A ________
ent
7
[ent] to Select
7 = MAX No
ent
0 = OMIT ZONES
[ent] to Select
Enter new
MAX number

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals