Galaxy 3 Series Programming Manual
156
Group Name Display
When viewing the groups assigned to an option, for example user code or outputs, simultaneously pressing the
# and keys displays the groups individually. The keypad displays the group number, name and the status of
the particular option being displayed. Press the # key to toggle the status of the group. To move to another
group press the A or B keys or enter the number of the group directly.
Notes on Groups
1. All zones default to group 1.
2. All keypads, user codes and outputs default to all system groups assigned.
3. Remove unused groups from user codes, otherwise the unused groups will set and unset even though
they are not programmed.
4. Final, Keyswitch and Exit can be programmed to function in regard to other groups during the
setting and unsetting procedures (refer to option 52 = PROGRAM ZONES).
5. Outputs can be assigned to any selection of groups. Output activation can be made dependent on the
set or unset status of the assigned groups (refer to option 53 = PROGRAM OUTPUTS).
6. After programming zones, codes, keypads and outputs into their various groups they remain pro-
grammed if the Group Mode function is disabled. Only Group 1 remains active.
7. The Galaxy control panels have multi-user software that allow several users to operate the system
simultaneously.
2=MAX
This option is used to program the Galaxy MAX/MicroMAX/MAX
3
access control readers. The MAX/
MicroMAX/MAX
3
can be fully integrated into the system, communicating on the AB lines and fully utilising the
facilities of the Galaxy control panel. If the MAX/MicroMAX/MAX
3
is programmed as a standalone module,
it is completely separate from the Galaxy; the panel does not monitor the module or share any of the facilities
or options with it.
Programming the MAX/MicroMAX/MAX
3
On selecting the MAX option, 1 = MAX Mode is displayed; press the ent key to select this function.
1 = MAX Mode
This option is used to enable the MAX functions and allow the MAX modules to be programmed (default is 0
= Disabled). When enabled, the options that are eligible for MAX programming are made available through-
out the menu, otherwise they do not appear or appear as Option not Available.
NOTE: If the MAX Mode is disabled following programming of MAX/MicroMAX/MAX
3
readers, the
readers remain operational, however, no further programming, including assigning next MAX/
MicroMAX/MAX
3
cards and fobs, is possible until the mode is enabled.
63 - Options (cont’d)
Current group name
Status of group
# key to toggle status
Selected group
A or B key to move
to other group
A2 Sales Dept SA2 Sales Dept S
A2 Sales Dept SA2 Sales Dept S
A2 Sales Dept S
[<],[>],#=CHANGE[<],[>],#=CHANGE
[<],[>],#=CHANGE[<],[>],#=CHANGE
[<],[>],#=CHANGE

Table of Contents

Other manuals for Honeywell Galaxy 3-520C

Related product manuals