Galaxy Flex Installer Manual Program Outputs [53]
127
01 Bells (Latch)
This output is activated on a full alarm event when the system is set, and is subject to the
Bell Time, Bell Delay and No. Re-arm parameters.
02 Strobe (Latch)
This output is activated on a full alarm event during the set state, and is subject to the Bell
Delay. It follows the Bell Time, but latches on after the last re-arm.
03 PA (Latch)
This output is activated whenever any of the PA zone types activate. The output is not
subject to the Re-arm parameter. It latches on and remains active until a valid code, with the
appropriate PA Reset level, is entered.
04 Intruder (Latch)
This output is activated on a full alarm event during the set state. Depending on the
programming of Force Restore [51.56], the intruder output restore is either subject to the
Confirm Time Window + unset or entry of a valid code with the appropriate system reset
level. Refer to the Force Restore [51.56] description for more information.
05 Tamper (Latch)
The Tamper output is activated whenever a circuit tamper or lid tamper occurs. The output
is not subject to the Re-arm parameter. It latches on and remains active until a valid code,
with the appropriate Tamper Reset level, is entered. The output is also activated on the first
entry of the engineer code when accessing engineer mode.
Note: The Tamper output is not activated when engineer access is authorized by the user.
07 Reset (Latch)
This output is used as a control line output to latch, freeze and reset movement detector
LEDs.
08 Switch DC (Pulse)
This output is used to power detectors that require a momentary power interruption to reset
them, for example, break glass or vibration detectors. It reverses its polarity (changes from
0 V to 12 V) for the period of the Pulse output mode when the setting procedure has been
initiated.
Note: When wiring detectors to a Switch d.c. output, connect the positive lead of the
detector to the 12 V terminal of a power supply and the negative lead to the Switch
d.c. output terminal. Do not change the Output Polarity to 1=Neg.
09 Set (Reflex)
The Set output is activated when the assigned groups on the system are set. It is a Reflex
output and follows the set and unset status of the groups.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals