Installation instructions
Vigilon panel
based Fire detection and alarm system
up to 2km
loop
Vigilon Fire System
GENT 2015
Designed to EN54 Pt 2 & 4
Healthy
15:45
Fault
System Fault
Tes t
Fire
Power
Power Fault
Fault/Dis
Disablement
Sounder
Previous
Next
Delay
Veri fy
Active
Fire Routing O/P
www.acornfiresecurity.com
www.acornfiresecurity.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Honeywell Gent Vigilon and is the answer not in the manual?

Honeywell Gent Vigilon Specifications

General IconGeneral
Event Log CapacityUp to 10, 000 events
Enclosure RatingIP30
TypeFire Alarm Control Panel
Max Number of Loops4
Battery Backup24V DC sealed lead-acid batteries
DisplayLCD
DimensionsVaries depending on the panel configuration
ComplianceEN54

Summary

Installation

Second Fix

Installation of second fix items after major building work is complete.

Fixture and Fittings

Installer responsibility to provide adequate fixtures and fittings based on product weight and size.

Cable Type and Routing

Ensuring correct cable type installation according to drawings and standards.

Earth Continuity

Power Supply

Mains Supply

Mains supply connection via unswitched 5A fused spur unit with disconnect device.

Local Manual Call Point

EN54 Information

System Wiring

Cable Separation

Physical separation of outgoing and return loop cables to minimise damage risk.

Lightning Protection

Consideration for lightning protection devices on external loop cables.

Cables

Requirements of Cables

Fire resisting cable classifications (PH30, PH120) and testing according to EN50200.

Mains Supply Cable

Standard fire resisting type meeting PH30 classification for mains supply.

Repeat Indicator to Panel Cable

Maximum 1Km cable distance for repeat indicator to panel connection.

Loop Cables

Enhanced Loop Cables

Approved EMC compliant cables for loop wiring with specific types listed.

Standard Loop Cables

Approved EMC compliant cables for loop wiring with specific types listed.

2.5mm² Loop Cable (2.5Km loop)

Cable reference for 2.5mm² loop cable, extending loop length to 2.5Km.

Network Cables

Enhanced Network Cables

Approved EMC compliant cables for network connections, including distance and core details.

Standard Network Cables

Approved EMC compliant cables for network connections, including distance and core details.

Specific Network Cable Types

Prysmian FP200 Flex Network Cable

Specific network cable from Prysmian (formally Pirelli) for panel to network node connections.

Prysmian FP200 Gold Network Cable

Specific network cable from Prysmian (formally Pirelli) for panel to network node connections.

Prysmian FP 400 Armoured Network Cable

Specific armoured network cable from Prysmian (formally Pirelli) for panel to network node connections.

Loop Circuit Design

Loop Card

Details on the Vigilon Loop Card (VIG-LPC-EN) and its capabilities.

Loop Cable Length

Definition and calculation of loop cable length, including spur circuits.

Loop Device Load and Length Calculations

Calculations for loop device load and length for 2Km loop cards.

Lumped vs. Distributed Alarm Device Loads

Distributed Alarm Device Load

Characteristics of alarm loads distributed evenly along the loop cable.

Lumped Alarm Device Load

Characteristics of alarm loads grouped together on a loop circuit.

Vigilon Loop Diagnostic Tool

Typical Vigilon System Overview

Addressable System Devices

List and description of various addressable devices used in the Vigilon system.

Conventional Products Interface Inputs

Details on conventional products connecting to interface inputs.

Vigilon Panel Features

Technical Data: Control Panel

Control Panel Interface Details

Plug-in Card Slots

Description of available slots for various interface cards like MCC, IO, and Loop cards.

RS232 and RS485 Connections

Configuration and limitations for RS232 and RS485 communication ports.

Control Panel Buttons and Indicators

Information on front panel controls, indicators, and access levels.

System Access Levels and Logs

Menus and Logs

Description of system menus and the types of logs available (Active, Historic, Event, Fire).

Batteries and Battery Box

Power Supply Specifications

Mains Supply Voltage and Fuses

Specifications for mains voltage, input current, and protective fuses.

Battery Charging Current

Nominal and EN54 Part 4 data for battery charging currents for VIG1-24 and VIG1-72.

EN54 Part 4 Data

Specific EN54 Part 4 data including quiescent and alarm loop currents.

Panel Installation Components

Mounting and Cable Entry Points

Semi-Flush Panel Mounting

VIG1-72 Battery Box and Rack Mounting

Battery Box for VIG1-72 Panel

Specifications and mounting options for the VIG1-72 battery box.

19 Inch Rack Mounting Frames

Description of rack mounting frames for panel and battery box installation.

Wiring the Battery Box

Cable Termination and Wiring Tests

Cable Termination on Enclosure

Methods for terminating MICC and softskin cables on panel enclosures.

Wiring Tests Precautions

Warning against high voltage insulation tests on connected cables.

Mains and Battery Supply Cables

Installation requirements for mains and battery supply cables before commissioning.

Mains Supply Installation

Terminals for External Circuits

Device Loop Circuits

Master Alarm Circuits

Clean Contacts Output

Auxiliary Relay Circuits

RS232 / RS485 Communication

Connecting a Remote Printer

Network of Systems

Network Connections and Wiring

Network Connections Diagrams

Illustrations of network connections between control panels and network nodes.

Network Wiring Guidelines

Recommendations for network wiring, emphasizing EMC compliant cables.

Fibre Optic Network Connections

Network Cable Screen Continuity

Minimising Network Crosstalk

Domain Bridge Across Networks

Methods of Domain Bridging

Overview of domain bridging techniques: RS232, modem, fibre optics, NPORT.

Star Connection for Domains

Illustration of a star connection topology for domain bridging.

Fibre Optic Domain Bridge Setup

RS232 Domain Bridge Setup

Domain Bridge using NPORT Module

Modem Domain Bridge Setup

Completion of Wiring Installation

S-Quad Sensor Details

S-Quad Base and IP21 Base

Details on the S-Quad base, IP21 gasket, and optional labels.

S-Quad Indicators and Dust Cover

Description of S-Quad LED indicators and the function of the dust cover.

S-Quad Sensor Siting Guidelines

Do's and Don'ts for Detector Placement

Metal Back Box Installation

In-Out Wiring to S-Quad Bases

Programmable Input/Output Configuration

Tools for S-Quad Installation and Maintenance

S-Quad Removal and Fitting Tools

Tools and procedures for removing and fitting the S-Quad device head.

S-Quad Dust Cover Tools

Tools for fitting and removing the S-Quad sensor dust cover.

Vigilon Panel Parts List

System Components and Products

Network Node and Domain Bridge Products

Details on Vigilon network nodes and domain bridge products like NPORT and modems.

Printers and Manuals

Information on available printer types and system manuals.

Related product manuals