Do you have a question about the Honeywell Gamewell FCI S3 Series and is the answer not in the manual?
Display | LCD display with backlight |
---|---|
Operating Temperature | 32°F to 120°F (0°C to 49°C) |
Type | Fire Alarm Control Panel |
SLC Loops | 1 or 2 loops |
Notification Appliance Circuits (NACs) | Up to 4 NACs |
Communication | Optional Ethernet, RS-232, and RS-485 |
Operating Voltage | 120/240V AC, 50/60 Hz |
Humidity Range | 10% to 93% relative humidity, non-condensing |
Compatibility | Compatible with Gamewell-FCI addressable devices |
Certifications | UL, FM, CSFM |
Provides an overview of the S3 Series Small Addressable Fire Alarm Control Panel.
Document detailing UL listing and specifications for the S3 Series.
Discusses limitations of smoke detectors, including environmental factors and fire types.
Explains limitations of heat detectors, focusing on property protection.
Covers precautions for reliable installation and long-term system operation.
Details compliance with FCC and Canadian regulations for radio emissions.
Describes the design and operation of the S3 Series FACP.
Lists UL-controlled documentation and resources for the S3 Series.
Details the main supply circuit and its wiring terminals and specifications.
Provides wiring diagrams and terminal designations for the SLP-E3 main board.
Explains wiring and ratings for SLC-PM and SLC95-PM signaling line circuits.
Covers the connection and specifications for various remote annunciators.
Details communication circuits like RPT-E3-UTP, FML-E3, FSL-E3, and DACT-E3.
Describes the power output circuits and their specifications.
Details the wiring and specifications for the releasing device circuit.
Explains the relay circuit outputs and their specifications.
Covers wiring requirements for Class 2 power-limited and non-power-limited circuits.
Details the LCD-SLP panel display, LED indicators, and audible/visual conditions.
Summarizes system operation types, including local and remote station configurations.
Lists key features of the SLP-E3 main board, including UL standard functions.
Defines the priority levels for displaying signals on the system.
Describes expected system responses to various conditions like Fire Alarm and Trouble.
Details uIP license and programming settings for CAMWorks.
Explains available menu selections for system programming.
Essential guidelines for periodic testing and servicing of the control panel.
Procedures for operational checks and battery maintenance.
Lists devices compatible with the SLP Main Board.
Details service type applications listed for the S3 Series System.
Lists modules required for various S3 Series system configurations.
Provides information on system power currents and maximum capacity.