S3 Series UL Listing Document — P/N LS10005-051GF-E:D3 3/09/2016 9
Standards Introduction
1.2 Standards
The S3 Series System complies with the following Standards:
Underwriters Laboratories Standards
The S3 Series System is suitable for the following signaling services that comply with the Underwriters
Laboratories Standards:
NFPA Standards
When the S3 Series System is configured and installed under the supervision of a Gamewell-FCI Factory
Trained and Certified Distributor, the S3 Series System complies with the requirements of the following
National Fire Protection Association (NFPA) Standards:
1.3 Product Models Nomenclature
Table 1.3.1 lists the nomenclature of the models included in each of the product line series that appear in this
Manual. To determine which models are associated with the particular series that is mentioned in this Manual,
refer to Table 1.3.1.
UL Standard 864 9th Edition:
Automatic Fire Detector Alarm Waterflow Alarm Releasing Device Service
Manual Fire Alarm Supervisory Automatic Smoke Alarm, non-coded
and master coded operation
NFPA 13 - Standard for Installation of Sprinkler Systems
NFPA 16 - Standard for Foam-Water Sprinkler and Foam-Water Spray Systems
NFPA 72 - National Fire Alarm Code:
Central Station Fire Alarm Systems Local Fire Alarm Systems
Auxiliary Fire Alarm Systems Remote Station Fire Alarm Systems
Proprietary Fire Alarm Systems
NOTE: Positive Alarm Sequence Standard:
UL 864 requires that PAS (Positive Alarm Sequence) be used only for alarm signals from
automatic alarm devices such as smoke detectors.
To provide the PAS Bypass function, an input device (such as a Monitor Module or an ASM switch
must be provided and programmed for this purpose, using the Configuration Programming Tool
called CAMWorks.
S3 Series Nomenclature
SLP-E3 SLC-PM SLC95-PM FLPS-7 LCD-SLP
E3 Series
®
E3 Control Panel ANX NGA RPT-E3-UTP INX
E3 Broadband ANX-SR ILI-MB-E3 DACT-E3 INCC
E3 Classic ANX-MR-FO ILI-S-E3 IPDACT-2 INCC-MIC
PM-9 ANX-MR-UTP ILI95-MB-E3 FPT-Works-WS INCC-TEL
PM-9G ANU-48 ILI95-S-E3 FPT-Mobile E3 LOC
LCD-E3 ASM-16 Fire Fighter’s Handset FPT-GATE-3 E3 LOC-TEL
AM-50 Series AA Series
AM-50-25 AM-50-70 AA-100 AA-120
ILI-E3 Series ILI95-E3 Series
ILI-MB-E3 ILI-S-E3 ILI95-MB-E3 ILI95-S-E3
INI-VG Series
INI-VGC INI-VGE INI-VGX
MS-7 Series
MS-7AF/ASF MS-7 MS-7LOB MS-7LR MS-7LRA
MS-7A
Apollo Series
MS-95/MS-95T PID-95/PID-95P BCE-95 RCE-95 SCE-95
CZI-95
Table 1.3.1 Product Models Nomenclature

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Gamewell FCI S3 Series and is the answer not in the manual?

Honeywell Gamewell FCI S3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGamewell FCI S3 Series
CategoryFire Alarms
LanguageEnglish

Related product manuals