Model | NFS-320SYS |
---|---|
Type | Fire Alarm Control Panel |
Intelligent Detectors | Yes |
Intelligent Modules | Yes |
Operating Temperature | 32°F to 120°F (0°C to 49°C) |
Relative Humidity | 10% to 93% non-condensing |
Loop Capacity | 318 devices per loop |
NAC Circuits | 4 |
Power Supply | 120VAC |
Power | 3A |
Battery Backup | Yes |
Communication | RS-485 |
Networking | Yes |
Weight | 25 lbs |
Certifications | UL, FM |
Introduces the NFS-320SYS as part of the ONYX Series, designed for various applications.
Highlights modular design, wireless integration, and CLSS platform connectivity.
Certified for seismic and approved for marine applications.
Features intelligent SLC, wireless tech, and high-speed networking up to 200 nodes.
Supports multiple communication options, VeriFire Tools, and QWERTY keypad.
Fast polling protocol, digital communication, multicolor LEDs for Walk Test.
Includes High-Sensitivity Photoelectric (VIEW), Multi-Criteria Detectors, and drift compensation.
Supports SWIFT wireless devices and ten independent hazards for releasing systems.
Discusses voice integration, power supply specs, and FSV-951/FCO-951 detector features.
Integration of intelligent aspiration smoke detectors into ONYX Series panels.
Details the all-digital FlashScan protocol for precision, speed, and device capacity.
Manages detector sensitivity, reduces false alarms, and offers pre-alarm options.
Patented feature allowing sensors to use readings from nearby sensors for decisions.
Covers Autoprogram, Keypad Program Edit, and VeriFire Tools for system programming.
Guidelines for placing equipment within chassis and cabinets.
Details CPU-320SYS FACP, NCA-2 Network Control Annunciator, and other core components.
Describes Network Communication Modules (NCM) and High-Speed Network Communication Modules (HS-NCM).
Details NCD, RPT-W/F/WF repeaters, and ONYXWorks graphics workstations.
Lists addressable charging power supplies and auxiliary power supplies with battery charger.
Details the NFC-50/100 Voice Evacuation Control Panel with digital message generator.
Lists compatible printers, modems, and annunciators for EIA-232 and EIA-485 ports.
Details various intelligent detectors including FWSG, FCO, FPC, FSCO, FPTI, FS-OSI-RI, FSP, FST, FSV series.
Lists intelligent aspiration smoke detectors compatible with ONYX Series panels.
Details CAB-4/CAB-5 Series enclosures, Marine System enclosures, and battery boxes.
Lists various annunciator flush and surface mount boxes, and backboxes for specific modules.
Includes CLSS Gateway, Digital Alarm Communicators, and LTE Cellular Communicators.
Summarizes system capacity including SLCs, detectors, modules, zones, and annunciators.
Details UL, ULC, FM, CSFM, and Fire Dept. of New York approvals for the control panel.
Covers US Coast Guard, Lloyd's Register, and American Bureau of Shipping approvals.
Lists compliance with UL, NFPA 72, IBC, and CBC standards for fire alarm systems.