Page 6 of 7 — DN-60637:N • 9/15/2022
B200S-IV: Ivory intelligent, programmable sounder base. ULC:
B200SA-IV.
B200SCOA-WH: White intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with CO
detectors. Based on B200SA. ULC listed.
B200SCOA-IV: Ivory intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with CO
detectors. Based on B200SA. ULC listed.
B200S-LF-WH: White, low-frequency version of B200S. See DN-
60054.
B200S-LF-IV: Ivory, low-frequency version of B200S.
B200SR-WH: White intelligent programmable sounder base, Tem-
poral 3 or Continuous tone. For retrofit installations replacing
B501BH series bases. See DN-60054. ULC: B200SRA-WH.
B200SR-IV: Ivory intelligent programmable sounder base, Temporal
3 or Continuous tone. For retrofit installations replacing B501BH
series bases. ULC: B200SRA-IV.
B200SR-LF-WH: White, low-frequency version of B200SR. See DN-
60054.
B200SR-LF-IV: Ivory, low-frequency version of B200SR.
FMM-1: FlashScan monitor module. See DN-6720.
FDM-1(A): FlashScan dual monitor module. See DN-6720.
FZM-1(A): FlashScan two-wire detector monitor module. See DN-
6720.
FMM-101(A): FlashScan miniature monitor module. See DN-6720.
FCM-1(A): FlashScan control module. See DN-6724.
FCM-1-REL(A): FlashScan releasing control module. See DN-
60390.
FRM-1(A): FlashScan relay module. See DN-6724.
FDRM-1(A): FlashScan dual monitor/dual relay module. See DN-
60709.
NBG-12LX: Manual pull station, addressable. See DN-6726.
N-MPS series: Manual pull stations, addressable and conventional.
For use in Canada only. See DN-5497 and DN-60629. ISO-X(A):
Isolator module. See DN-2243.
ISO-6(A): Six fault isolator module. See DN-60844.
XP6-C(A): FlashScan six-circuit supervised control module. See
DN-6924.
XP6-MA(A): FlashScan six-zone interface module; connects intelli-
gent alarm system to two-wire conventional detection zone. See DN-
6925.
XP6-R(A): FlashScan six-relay (Form-C) control module. See DN-
6926.
XP10-M(A): FlashScan ten-input monitor module. See DN-6923.
ENCLOSURES, CHASSIS, AND DRESS PLATES
CAB-4 Series Enclosure: NFS-320SYS can mount in a standard
CAB-4 Series enclosure. See DN-6857 for CAB-4 options.
CAB-5 Series Enclosure: NFS-320SYS can mount in CAB-5
Series enclosures designed for INSPIRE panels, using CHS-ADP
adapter plate. See DN-62113 for CAB-5 options.
CAB-BM Marine System: Protects equipment in shipboard and
waterfront applications. Also order BB-MB for systems using
100 AH batteries. For a full list of required and optional equipment,
see DN-60688.
NFS-LBB: Battery Box (required for batteries larger than 26 AH).
NFS-LBBR: Same as above, but red.
SEISKIT-320/B26: Seismic mounting kit. Required for seismic-certi-
fied applications with NFS-320 and BB-26. Includes battery bracket
for two 26 AH batteries.
SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes battery
bracket for two 26 AH batteries.
SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket
for two 55 AH batteries.
Backboxes
NOTE: “C” suffix indicates ULC-Listed modell:
ABF-1B Annunciator Flush Box.
ABF-1DB(C) Annunciator Flush Box with Door.
ABF-2B Annunciator Flush Box
ABF-2DB(C) Annunciator Flush Box with Door
ABF-4B Annunciator Flush Box
ABS-1TB(C) Annunciator Surface Box
ABS-1B(C) Annunciator Surface Box
ABS-2B Annunciator Surface Box
ABS-2D(C) Annunciator Surface Box
ABS-4D(C) Annunciator Surface Box
BB-UZC: Backbox for housing the UZC-256. Required for NFS-320
applications. Black. For red, order BB-UZC-R.
OTHER OPTIONS
CGW-MB: CLSS Gateway for Internet/cloud-based communication
between the FACP and peripheral devices. See HON-62034.
HON-CGW-MBB: CLSS Gateway, pre-installed in a cabinet. See
HON-62034.
411: Slave Digital Alarm Communicator. See DN-6619.
411UDAC: Digital Alarm Communicator. See DN-6746.
IPDACT-2/2UD, IPDACT Internet Monitoring Module: Connects to
primary and secondary DACT telephone output ports for internet
communications over customer-provided Ethernet connection.
Requires compatible Teldat VisorALARM Central Station Receiver.
Can use DHCP or static IP. See DN-60408.
IPSPLT: Y-adapter option allow connection of both panel dialer out-
puts to one IPDACT-2/2UD cable input.
IPENC: External enclosure for IPDACT, includes IPBRKT mounting
bracket; Red. For Black order IPENC-B.
HWF2V-COM: LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, Verizon LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup. Con-
nects to the primary and secondary ports of a DACT. See DH-62010.
(For Canadian applications order IPGSM-4GC. See DH-60771.)
HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, AT&T LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup. Con-
nects to the primary and secondary ports of a DACT. (For Canadian
applications order IPGSM-4GC. See DH-60771.)
NOTE: For other options including compatibility with retrofit equipment,
refer to the panel's installation manual, the SLC manual, and the Device
Compatibility Document.