- 2 -
T C V
-
V
+
T NC
5
Ground +12V
Zone
#
Zone
COM
Zone
#
Zone
COM
Tamper
30 mA
25 VDC
Power
13 mA
9-15 VDC
(UL: 9.5-15 VDC)
Alarm
30 mA
25 VDC
6 4 2 15 3
22-20 AWG
(0.31-0.52mm
2
)
2
2
1
T C V
-
V
+
T NC
6 4 2 15 3
Panel / Panneau / Panel / Controle
Sensor / Détecteur / Sensor / Sensor
30 sec
30
0
45
20
10
6
ON
LED
1/2 sec.
hold 4x
< 4’ (1.2m)
Walk Test Reset
1. Close the sensor and apply power to the sensor. Initialization is complete
when the LED stops flashing slowly (about 30 seconds).
2. Walk through the detection area and observe the LED.
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters
normal operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight
feature (see Walk Test Reset, above).
Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable Dip switch setting.
7
PLAN VIEW
ALL ZONES
Top View
Vue de dessus
Vista Desde Arriba
Vista Superior
Side View
Vue de coté
Vista Lateral
Vista Lateral
7.5ft
2.3m
0ft
0m
7ft
2m
13ft
4m
20ft
6m
27ft
8m
33ft
10m
53ft
16m
47ft
14m
40ft
12m
A B C D
7ft
2 m
0
0
13ft
4 m
20ft
6 m
27ft
8 m
33ft
10 m
40ft
12 m
7ft
2 m
13ft
4 m
20ft
6 m
27ft
8 m
33ft
10 m
40ft
12 m
7ft
2 m
13ft
4 m
20ft
6 m
27ft
8 m
33ft
10 m
40ft
12 m
46ft
14 m
53ft
16 m
LED
Power
Up
Walk Test Normal Trouble
Red
Slow
Blink
ON
Alarm
ON
Alarm
Fast
Blink
Zones / Zones / Zonas / Zonas
A
2
Look-down / Basses / Vista Zona 0 /
Vigilância inferior
B
18
Lower / Courtes / Cercana/ Mais baixas
C
20
Intermediate / Intermédiaires / Intermedia /
Intermédias
D
54
Long / Longues / Largo Alcance / Longo
alcance
Look down
finger
s are
only
enabled
when
look down
is enabled