9.1.2. Basic settings for commissioning - time, raw water
hardness, regeneration time and cleaning function
Display Current time flashes
1. Set the time by pressing + or -
2. Confirm with MENU / OK
Display Hardness flashes
1. Set the raw water hardness by pressing + or -
2. Confirm with MENU / OK
Display Regeneration time flashes
1. Confirm with MENU / OK
Anzeige Clean (Reinigungsfunktion) blinkt (bei KS10S-30)
1. Confirm with MENU / OK
9.1.3. Setting the mix water hardness
1. Setting the mix water hardness by turning the screw at the
base of the diluting device
Use screwdriver
Turn counter-clockwise = increase water hardness on
output side
Turn clockwise = decrease water hardness on output
side
2. Check the mix water hardness at a tapping point
Open tapping point completely to ensure sufficient flow
3. Readjust by turning the screw if necessary
Hex allen wrench needed - M4mm
9.1.4. First Regeneration
1. Start regeneration
Press the Regeneration key for 5 seconds
•Display Regeneration active flashes
The time is displayed in the display during the regene-
ration process
2. After the end of the regeneration
•Display Regeneration active goes out.
The time is displayed
3. The device is ready for operation
There is a connection to the power supply
The hardness of the raw water can be inquired from the
water distribution company.
Factory setting for start time for regeneration: 2:00 AM
Start time can be modified by pressing + and -
Factory setting is Clean: On
Factory setting can be modified by pressing + and -
Modifying the factory setting is not recommended
Factory setting for rinsing duration: 4 minutes
AKTUELLE ZEIT
HÄRTE
REGENERATION
ZEIT
It is recommended to set a residual water hardness of at
least 8°dH to avoid corrosion damages.
It is recommended to check the output water hardness
regularly (2 times a year).