1.4 UNITS AND ACCESSORIES SUPPLIED
1.4.1 KI 208 VOR Indicator
066-3056-00
066-3056-02 Antireflective lens
1.4.2 KI 209 ILS Indicator
066-3056-01
066-3056-03 Antireflective lens
1.4.3 Bendix/King Equipment Installation Kit (P/N 050-01550-0000) which includes
mating connectors, mounting hardware, etc., is as follows:
VOR/LOC:
Input Impedance:
Nominal Composite Input Level:
Localizer Sensitivity:
OMNI Accuracy:
OMNI Sensitivity:
External Load:
50 k ohms, nominal.
LOC: 0.33 ±10% Vrms.
VOR: 0.50 ±10% Vrms ARINC phased.
4 dB tone ratio will give 3 dot scale deflection.
±2° max error, ±1° typical.
±10° off course gives full scale deflection.
ARINC autopilot deviation (two 1 k loads).
GLIDESLOPE DEVIATION
METER:
Input Impedance:
Deflection Sensitivity:
1 k ±5% ohms.
150 ±5% uA for full scale deflection.
GLIDESLOPE FLAG:
Input Impedance:
Deflection Sensitivity:
1 k ±5% ohms minimum.
125 uA for flag to leave stop.
260 uA maximum for fully concealed flag.
TABLE 1-1 Technical Characteristics KI 208, KI 209